General Information; Model Numbers; Dispenser Installation - Manitowoc RN Nugget Installation, Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

Model Numbers

This manual covers the following models:
Self-Contained Air-Cooled
RN0408A
RN1008A
RN1408A
!
Remove all ice machine panels before lifting and
installing.
!
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge,
unless
supervision concerning use of the appliance by a
person responsible for their safety.
4

General Information

Self-Contained Water-Cooled
RN1009W
RN1409W
Warning
Warning
they
have
been
Section 1
QuietQube Head
RN1078C
RN1478C

DISPENSER INSTALLATION

No adapter is needed for machines that match the
size of the dispenser unless required by the
dispenser manufacturer.
No deflector is required unless specified by the
dispenser manufacturer.
A bin thermostat to control ice level is recommended.
Ice machine must be secured to dispenser.
Extension ice discharge tube (supplied with ice
machine) must be installed in dispenser applications
- Unscrew factory installed ice discharge tube and
install extended ice discharge tube to lower the level
given
of ice in the dispenser. Removal and installation must
be performed from the ice machine compartment (top
down) and not from the dispenser compartment
(bottom up).
All dispenser manufacturers require a kit be
installed for Nugget type ice. Contact the dispenser
manufacturer for the correct adapter and nugget
dispensing kit for your specific model dispenser.
RFC Remote Condensing Unit
RNC1075
RNC1475
! Caution
Part Number 000007282 4/10