Mitsubishi Electric MXZ-2C30VA Service Manual page 314

Outdoor unit
Hide thumbs Also See for MXZ-2C30VA:
Table of Contents

Advertisement

MXZ-6C122VA COOLING
Indoor units
combination
Unit A
42+60
3.75
42+71
3.49
50+50
4.45
4.23
50+60
50+71
3.97
60+60
4.80
60+71
4.44
71+71
4.85
15+15+15
1.50
1.50
15+15+20
15+15+22
1.50
15+15+25
1.50
15+15+35
1.50
15+15+42
1.50
15+15+50
1.54
15+15+60
1.48
15+15+71
1.43
15+20+20
1.50
15+20+22
1.50
15+20+25
1.50
15+20+35
1.50
15+20+42
1.48
15+20+50
1.45
15+20+60
1.41
15+20+71
1.36
15+22+22
1.50
15+22+25
1.50
15+22+35
1.50
15+22+42
1.42
15+22+50
1.41
15+22+60
1.38
15+22+71
1.33
15+25+25
1.50
15+25+35
1.50
15+25+42
1.50
15+25+50
1.48
15+25+60
1.44
15+25+71
1.31
15+35+35
1.45
15+35+42
1.45
15+35+50
1.44
15+35+60
1.32
15+35+71
1.21
15+42+42
1.35
15+42+50
1.35
15+42+60
1.26
Cooling Capacity (kW)
Unit B
Unit C
Unit D
Unit E
5.35
-
-
-
5.91
-
-
-
4.45
-
-
-
5.07
-
-
-
5.63
-
-
-
4.80
-
-
-
5.26
-
-
-
4.85
-
-
-
1.50
1.50
-
-
1.50
2.00
-
-
1.50
2.20
-
-
1.50
2.50
-
-
1.50
3.50
-
-
1.50
4.20
-
-
1.54
5.13
-
-
1.48
5.93
-
-
1.43
6.75
-
-
2.00
2.00
-
-
2.00
2.20
-
-
-
2.00
2.50
-
2.00
3.50
-
-
1.97
4.15
-
-
1.93
4.82
-
-
1.87
5.62
-
-
1.81
6.43
-
-
2.20
2.20
-
-
2.20
2.50
-
-
2.20
3.50
-
-
2.09
3.99
-
-
2.07
4.71
-
-
2.02
5.51
-
-
1.96
6.31
-
-
2.50
2.50
-
-
2.50
3.50
-
-
2.50
4.20
-
-
2.47
4.94
-
-
2.40
5.76
-
-
2.18
6.20
-
-
3.38
3.38
-
-
3.39
4.06
-
-
3.36
4.80
-
-
3.09
5.29
-
-
2.83
5.75
-
-
3.78
3.78
-
-
3.77
4.49
-
-
3.52
5.03
-
-
Outdoor unit
power consumpution (kW)
Unit F
Total
9.10
-
(2.80-9.70)
(0.830-3.160)
9.40
-
(2.90-10.00)
(0.820-3.200)
8.90
-
(2.80-9.50)
(0.840-3.130)
9.30
-
(2.90-9.90)
(0.830-3.190)
9.60
-
(2.90-10.20)
(0.810-3.230)
9.60
-
(2.90-10.20)
(0.810-3.230)
9.70
-
(2.90-10.30)
(0.810-3.240)
9.70
-
(2.90-10.30)
(0.810-3.240)
4.50
-
(2.90-6.00)
(0.950-3.280)
5.00
-
(2.90-6.80)
(0.950-3.560)
5.20
-
(2.90-7.10)
(0.950-3.670)
5.50
-
(3.00-7.50)
(0.950-3.810)
6.50
-
(3.20-8.50)
(0.900-2.500)
7.20
-
(3.20-9.20)
(0.890-3.000)
8.20
-
(3.20-9.80)
(0.890-3.400)
8.90
-
(3.30-10.40)
(0.890-3.750)
9.60
-
(3.30-11.00)
(0.890-4.110)
5.50
-
(3.00-7.50)
(0.950-3.810)
5.70
-
(3.00-7.80)
(0.950-3.910)
6.00
-
(3.00-8.30)
(0.950-4.090)
7.00
-
(3.20-8.90)
(0.890-2.790)
7.60
-
(3.20-9.60)
(0.890-3.280)
8.20
-
(3.20-10.10)
(0.890-3.580)
8.90
-
(3.30-10.60)
(0.890-3.870)
9.60
-
(3.30-11.20)
(0.890-4.230)
5.90
-
(3.00-8.10)
(0.950-4.020)
6.20
-
(3.10-8.40)
(0.930-3.300)
7.20
-
(3.20-9.20)
(0.890-3.000)
7.50
-
(3.20-9.70)
(0.890-3.340)
8.20
-
(3.20-10.20)
(0.890-3.640)
8.90
-
(3.30-10.70)
(0.890-3.930)
9.60
-
(3.30-11.20)
(0.890-4.230)
6.50
-
(3.20-8.50)
(0.900-2.500)
7.50
-
(3.20-9.50)
(0.890-3.220)
8.20
-
(3.20-9.90)
(0.890-3.460)
8.90
-
(3.30-10.40)
(0.890-3.750)
9.60
-
(3.30-10.90)
(0.890-4.050)
9.70
-
(3.30-11.30)
(0.890-4.290)
8.20
-
(3.20-10.10)
(0.890-3.580)
8.90
-
(3.30-10.50)
(0.890-3.810)
9.60
-
(3.30-10.90)
(0.890-4.050)
9.70
-
(3.30-11.30)
(0.890-4.290)
9.80
-
(3.30-11.40)
(0.890-4.360)
8.90
-
(3.30-10.90)
(0.890-4.050)
9.60
-
(3.30-11.20)
(0.890-4.230)
9.80
-
(3.30-11.40)
(0.890-4.360)
188/266
Current
Power
(A)
factor (%)
2.990
13.13
99
3.020
13.26
99
2.970
13.04
99
3.010
13.22
99
3.040
13.35
99
3.040
13.35
99
3.050
13.39
99
3.050
13.39
99
1.200
5.27
99
1.308
5.75
99
1.352
5.94
99
1.417
6.22
99
1.633
7.17
99
1.865
8.19
99
2.350
10.32
99
2.725
11.97
99
3.100
13.61
99
1.417
6.22
99
1.460
6.41
99
1.525
6.70
99
1.768
7.77
99
2.059
9.04
99
2.350
10.32
99
2.725
11.97
99
3.100
13.61
99
1.503
6.60
99
1.568
6.89
99
1.865
8.19
99
2.011
8.83
99
2.350
10.32
99
2.725
11.97
99
3.100
13.61
99
1.633
7.17
99
2.011
8.83
99
2.350
10.32
99
2.725
11.97
99
3.100
13.61
99
3.200
14.05
99
2.350
10.32
99
2.725
11.97
99
3.100
13.61
99
3.200
14.05
99
3.290
14.45
99
2.725
11.97
99
3.100
13.61
99
3.290
14.45
99