EASEPAL EC-385A Maintenance Service Manual page 4

Table of Contents

Advertisement

Available languages

Available languages

No tapping
06
手 控 器 上 按 键 无
反映
No response for
all the buttons
of controller
不升倒背
07
Backrest can't
recline or lift
小腿不能升降
08
calves-rest can`t
lift or recline
The terminals on main PCB
and wires are poorly connected
②、敲击电机坏
Tapping motor failed
③、中心板坏掉 Main PCB failed
①、端子接触不良或线材接触不良
The terminals and wires are
poorly connected
②、手控器 PCB 板坏
The PCB in the controller failed
①、电动推杆连接线未接插到位
The
terminal
of
actuator
and wires are poorly
connected
②、电动推杆坏
The electrically operated
pusher failed
③、中心板坏
Main PCB failed
①、电动推杆连接线未接插到位
The
terminal
of
actuator and wires are poorly
connected
②、电动推杆坏
The calves-rest failed
③、中心板坏 Main PCB failed
Plug the terminal well
②、更换机芯
Replace gear box
③、更换中心板
Replace the main PCB
①、将端子接插到位或是更换线材。
Plug the terminal well or
replace the wires
②、更换手控器
Replace the controller
①、将连接线接插到位
reclining
Plug the terminal well
②、更换电动推杆
Replace the
③、更换中心板
Replace main PCB
①、将连接线接插到位
calves-rest
Plug the terminal well
②、更换电动推杆
Replace
actuator
③、更换中心板
Replace main PCB
reclining actuator
the
calves-rest

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents