c. <Destination setting>
Destination can be set by clicking each model name in "SET DESTINATION."
Confirm the model name by clicking "GET DEVICE ID" after setting change. (If incorrect, it can be changed before
turning the unit OFF/ON.)
<EEPROM reset>
When "EEPROM CLEAR" is checked, the EEPROM is reset after the shipment inspection pattern printing.
(At EEPROM reset, the main waste ink counter value is re-set to 3,000mg.)