Download Print this page

Connectivity Options - National Instruments R Series Intelligent DAQ PCI/PXI-783xR Getting Started Manual

R series intelligent daq

Advertisement

The +5V terminals on the I/O connector supply +5 V referenced to D GND. Use these terminals to
power external circuitry. All NI 78xxR devices are equipped with a fuse to protect the supply from
overcurrent conditions. Refer to the R Series Intelligent DAQ User Manual, available at
, for information about the device-specific fuses.
manuals

Connectivity Options

Accessing the signals on the I/O connectors requires at least one cable and one signal accessory. Table 1
summarizes the National Instruments connectivity options available for use with the NI 78xxR device.
Cable
*
SHC68-68-RMIO
(NI Recommended)
SHC68-68-RDIO
(NI Recommended)
SH68-C68-S
CAT 5 Ethernet
*
crossover cable
*
NI 783xR/784xR/785xR devices only.
For a diagram of the twisted pairs in the SHC68-68-RMIO and SHC68-68-RDIO cables and the signals to which they
correspond, go to
ni.com/info
For detailed information about connecting I/O signals, refer to the NI R Series Intelligent DAQ User
Manual, available at
© National Instruments Corporation
Table 1. R Series Connectivity Options
Connector
Accessory
0
NI SCB-68
1, 2
NI SCB-68
0, 1, 2
NI SCB-68
and enter the info code
ni.com/manuals
High-performance shielded cable wired
specifically for signal connection from the
RMIO connector
block to provide higher signal integrity and noise
immunity.
High-performance shielded cable wired
specifically for signal connection from the
RDIO connector
block to provide higher signal integrity and noise
immunity.
Basic shielded cable for signal connection from
the RMIO or RDIO connector to the NI SCB-68
terminal block for noise reduction.
For use with the NI PXI-78xxR running the
LabVIEW Real-Time Module, if the real-time
PXI system is not configured on a network.
To connect the PXI system to a network port, use
a standard CAT 5 10/100Base-T Ethernet cable.
.
rdrmio
.
7
ni.com/
Description
to the NI SCB-68 terminal
to the NI SCB-68 terminal
Getting Started with R Series Intelligent DAQ

Advertisement