Download Print this page

National Instruments R Series Intelligent DAQ PCI/PXI-783xR Getting Started Manual page 10

R series intelligent daq

Advertisement

Adding Analog Output to the FPGA Application
To expand the LabVIEW FPGA application to include analog output, complete the following steps:
1.
On the block diagram of Analog Input (FPGA).vi, insert a new frame between the first and second
frames of the Flat Sequence structure by right-clicking the divider between the first two frames and
selecting Insert Frame from the shortcut menu, as shown in the following figure.
2.
In the Project Explorer window, right-click the FPGA target and select New»FPGA I/O.
3.
In the New FPGA I/O dialog box, expand Connector0 and select AO0.
Note
This example reflects the naming conventions and graphic interface of LabVIEW 8.5. Items
such as FPGA I/O resources may appear differently if you are using earlier versions of LabVIEW.
4.
Click Add, then click OK.
5.
Click Connector0/AO0 in the Project Explorer window and drag it into the second frame of the
Flat Sequence structure on the block diagram of the FPGA VI. The FPGA I/O Node is created
automatically.
Getting Started with R Series Intelligent DAQ
10
ni.com

Advertisement