Quick Start Guide

FieldPoint cFP-21xx
What You Need to Get Set Up
cFP-21xx LabVIEW RT controller
Mounting hardware (DIN rail,
panel-mount, or rack-mount
accessory)
I/O module(s)
cFP-BP-x backplane, connector
blocks, cables
11–30 VDC power supply
Accessories: Ethernet cable,
number 2 Phillips screwdriver
PC running Windows
FieldPoint software 4.1.1 or later
LabVIEW Real-Time Module

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments Compact FieldPoint Mounting Accessories cFP-21xx

  • Page 1: Quick Start Guide

    Quick Start Guide FieldPoint cFP-21xx ™ What You Need to Get Set Up • cFP-21xx LabVIEW RT controller • Mounting hardware (DIN rail, panel-mount, or rack-mount accessory) • I/O module(s) • cFP-BP-x backplane, connector blocks, cables • 11–30 VDC power supply •...
  • Page 2 1. Mount the Compact FieldPoint Backplane You can mount the cFP-BP-x backplane on a 35mm DIN rail, on a panel, or in a standard 19 in. rack. Before using any of these mounting methods, record the serial number from the back of the backplane. Each set of mounting instructions in this document includes an instruction to connect the protective earth (PE) ground terminal on the cFP-BP-x backplane to the system safety ground.
  • Page 3 If you are using UL Recognized I\O modules with the Compact Caution FieldPoint system, you must install the entire system in a suitably rated, UL Listed NEMA or IP enclosure. © National Instruments Corporation 4 slots = 246 mm (9.68 in.) 8 slots = 441 mm (17.4 in.) Cabling Clearance Cooling Outline 51 mm (2 in.) All Around...
  • Page 4 NI recommends that you use one of the mounting systems Caution described in this document. If you decide to use a custom mounting solution, make sure that the screws you use are short enough to fit in the holes in the backplane. The screw holes are 5 mm (0.2 in.) deep. cFP-21xx Quick Start Guide ni.com...
  • Page 5 Do not use screws longer than 5/16 in. to fasten the Caution panel-mount plates to the backplane. 102 mm (4 in.) © National Instruments Corporation T IO IN S 457 mm (18 in.) cFP-21xx Quick Start Guide...
  • Page 6 104.78 mm (4.1 in.) 63.50 mm 127.00 mm (2.5 in.) (5.0 in.) 22.23 mm (0.9 in.) 102 mm (4 in.) cFP-21xx Quick Start Guide 440.94 mm (17.4 in.) 260 mm (10.25 in.) ni.com...
  • Page 7 The DIN rail mounting kit is NI part number 778614-01. 1. Fasten the DIN rail clip to the cFP-BP-4 using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the clip. © National Instruments Corporation 104.74 mm (4.1 in.) 63.46 mm (2.5 in.)
  • Page 8 Do not use screws longer than 5/16 in. to fasten the DIN rail Caution clip to the backplane. 2. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip. 3. Press down firmly on the backplane to compress the spring until the clip locks in place on the DIN rail.
  • Page 9 1. Fasten the rack-mount bracket to the back of the cFP-BP-x using the captive screws on the bracket. 2. Bolt the rack-mount accessory to a standard 19 in. rack. © National Instruments Corporation T IO IN S cFP-21xx Quick Start Guide...
  • Page 10 3. Connect the PE ground terminal on the cFP-BP-x to safety ground. Disconnect power before removing the backplane from the Caution DIN rail. cFP-21xx Quick Start Guide T IO IN S ni.com...
  • Page 11 5. Using a number 2 Phillips screwdriver with a shank of at least 64 mm (2.5 in.) length, tighten the captive screws to 1.1 N · m (10 lb · in.) of torque. T I O I N S © National Instruments Corporation cFP-21xx Quick Start Guide...
  • Page 12 3. Install I/O Modules on the Backplane 1. Align the captive screws on the I/O module with the holes on the backplane. 2. Press firmly to seat the I/O module on the backplane. 3. Using a number 2 Phillips screwdriver with a shank of at least 64 mm (2.5 in.) length, tighten the captive screws to 1.1 N ·...
  • Page 13 4. Using a number 2 Phillips screwdriver with a shank of at least 64 mm (2.5 in.) length, tighten the captive screws to 1.1 N · m (10 lb · in.) of torque. 5. Repeat this procedure to install additional connector blocks on the backplane. © National Instruments Corporation cFP-21xx Quick Start Guide...
  • Page 14 Caution Ethernet installation, do not use a cable longer than 100 m. If you are using a 100 Mbps Ethernet network, National Instruments recommends using a Category 5 shielded twisted-pair Ethernet cable. If the host PC is already configured on a network, you must configure the cFP-21xx on the same network.
  • Page 15 I/O module. 4. Use a separate power supply for each module that needs external power. Cascading power defeats isolation between the cascaded Caution modules. © National Instruments Corporation 11–30 VDC Backup – 11–30 VDC Primary Power Supply cFP-21xx Quick Start Guide...
  • Page 16 7. Power Up the cFP-21xx Check the DIP switches on the controller, making sure that the RESET IP switch is in the OFF position. Plug in each power supply to the Compact FieldPoint system. The cFP-21xx runs a power-on self test (POST) that takes several seconds.
  • Page 17 LabWindows/CVI instrument driver only if it finds the corresponding development software installed. 2. Close all other applications. 3. Insert the National Instruments FieldPoint Software CD into the CD-ROM drive on your computer. 4. Follow the onscreen instructions to complete the installation.
  • Page 18 Misuse of the product can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instruments for repair.
  • Page 19 Measurement categories establish standard Measurement categories are defined in electrical safety standard IEC 61010-1. Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation. © National Instruments Corporation cFP-21xx Quick Start Guide...
  • Page 20 impulse withstand voltage levels that commonly occur in electrical distribution systems. The following is a description of measurement categories: • Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage.
  • Page 21: Specifications

    Compatibility ... IEEE802.3 Communication rates ... 10 Mbps, 100 Mbps, auto-negotiated Maximum cabling distance... 100 m/segment Maximum power to connected I/O modules ... 9 W Maximum number of banks... Determined by network topology © National Instruments Corporation cFP-21xx Quick Start Guide...
  • Page 22: Serial Ports

    Memory cFP-2100... 64 MB nonvolatile; cFP-2110... 64 MB nonvolatile; cFP-2120... 128 MB nonvolatile; Memory lifetime (nonvolatile)... 300,000 writes per sector For information about the memory used by the LabVIEW Real-Time Module and the operating system, go to Serial Ports cFP-2100... One RS-232 serial port cFP-2110...
  • Page 23: Power Requirement

    Screw-terminal wiring ... 16–26 AWG copper conductor wire with Torque for screw terminals ... 0.5–0.6 N · m (4.4–5.3 lb · in.) Weight... 278 g (9.8 oz) © National Instruments Corporation , verified by 5 s test requirements) 7 mm (0.28 in.) of insulation stripped from...
  • Page 24: Shock And Vibration

    Environmental FieldPoint modules are intended for indoor use only. For outdoor use, they must be installed in a suitable sealed enclosure. Operating temperature ... –40 to 70 °C Storage temperature ... –40 to 85 °C Humidity ... 10 to 90% RH, noncondensing Maximum altitude...
  • Page 25: Electromagnetic Compatibility

    This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: Low-Voltage Directive (safety)... 2006/95/EC Electromagnetic Compatibility Directive (EMC) ... 2004/108/EC © National Instruments Corporation ni.com/certification , search by model cFP-21xx Quick Start Guide...
  • Page 26 Refer to the Declaration of Conformity (DoC) for this product for Note any additional regulatory compliance information. To obtain the DoC for this product, visit number or product line, and click the appropriate link in the Certification column. Cabling The table below shows the standard Ethernet cable wiring connections for both normal and crossover cables.
  • Page 27: Where To Go For Support

    Where to Go for Support The National Instruments Web site is your complete resource for technical support. At you have access to everything from ni.com/support troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.
  • Page 28 National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instrumetns Patent Notice at...

Table of Contents