1. Function
• This is a switch that checks whether the door is open or closed.
• If the user opens the door, this switch disconnects power supply to the
motor and turns the lamp on.
• If the user closes the door, this switch connects power supply to the
motor and turns the lamp off.
2. Specification
• A push switch - stroke 70mm, tree terminals
pushed-down : COM and NO are closed (NO are connected to motor)
free state : COM and NC are closed (NC are connected to door lamp)
• Electric rating : 7.5A 125V
• Type name : SPE110F
3. Checking method of malfunction
• This switch applies power to the motor when the door is closed and to the lamp when the door is
opened.
• Select a program and press the start button.
• As the drum begins rotating, check if the lamp is turned on after opening the door.
• If the drum does not rotate, check the door switch contact.
Check a belt switch and fan thermostat also for the problem.
• If the lamp is still off while the drum is running, remove front panel assembly and check if 120v voltage is applied
to the lamp.
• If 120v voltage is not applied to the lamp, replace the door switch.
If the lamp is off even though the 120v voltage is being applied, replace the lamp.
4. Procedure of replacement
1Remove top plate
2Remove front panel assembly
3Remove cabinet front assembly
4 Remove the wires. Press both ends of the switch and pull.
5 Assemble the parts in reverse order.