Solid fuel burning zero clearance fireplace
Hide thumbs Also See for High Country NZ6000:

Advertisement

4. Electrical Connection
a) Remove the junction box covers on the unit and the
blower.
b) Removing the junction box cover on the unit exposes 4
black, labeled wires:
Two wires labelled "by-pass" - go to by-pass (summer)
switch (not supplied - overides the thermally activated
switch enabling the user to run the blower without heat).
Important:
Marrett by-pass (summer) switch wire leads sepa-
rately (do not connect together),
rately (do not connect together),
rately (do not connect together),
rately (do not connect together), if the by-pass
rately (do not connect together),
switch is not desired.
One wire labelled "blower" - connects to KB-35 rheostat
(not supplied) and then KB-35 blower wire connects to
white blower wire.
One wire labelled "L1" - connects to power (hot lead).
c) Removing the junction box cover on the blower exposes
3 coloured wires:
One black wire - connects to power "L2" (neutral lead).
One green wire - connects to ground.
One white wire - connects to KB-35 rheostat (not supplied)
See above.
5. Connect the 6" liner to the unit and blower collars. Se-
cure using 3 screws on each end and seal with caulking.
Liner supplied stretches to a maximum of 10'.
Liner supplied stretches to a maximum of 10'.
Liner supplied stretches to a maximum of 10'.
Liner supplied stretches to a maximum of 10'.
Liner supplied stretches to a maximum of 10'.
sepa-
sepa-
sepa-
sepa-
6. Insert the filter into the grill. Foam gasket (
stripping) between the grill and blower housing is recom-
mended, but not supplied.
The blower filter is washable.
7. The bottom lip of the grill latches over the bottom lip of
the housing. Use two screws to secure the top of the grill to
the facing.
The circulation air inlet pipe must terminate outside of the
fireplace enclosure to ensure proper air flow around the
firebox.
The 6" circulation air inlet pipe may be connected to either
the NZ64 blower kit or the NZ150-KT kit.
Avoid terminating higher than the bottom of the doors on
the unit to prevent air flow reversal.
An optional opening is
covered on the other side of the unit. If this loca-
tion is preferred, switch the cover plate and collar.
NZ150-KT KIT
NZ150-KT KIT
NZ150-KT KIT
NZ150-KT KIT
NZ150-KT KIT
W415-0594 / A / 02.15.07
21
1
/
" weather
2