Selecting the installation site

Consider the following:
To meet regulatory RF exposure requirements, install the AP and any
external antennas at least 40 cm (15.75 inches) from any person.
Install APs away from RF-emitting electronic devices, such as microwave
ovens.
Do not install APs in a location where water seepage or condensation
occurs.
Do not place the AP on a metal surface.
Install the AP where there are no obstacles and wireless clients can receive
a strong signal from the AP.
Installation
The AP can be mounted on a non-metallic table or shelf, a wall, or a ceiling.
When mounting on a wall or ceiling, mount the AP bracket first, and then
attach the AP to the bracket.
See also the HP 425 Wireless 802.11n Access Points Installation Guide.

Preparing for installation

HP recommends that you connect power and verify the Ethernet cable and
LEDs before you install the AP in a hard-to-reach location.
Record the MAC address and AP serial number for future reference.
If part of the power line is routed outdoors, connect the AP power cord to a
user-supplied power strip with lightning protection.
Placing the AP on a table or shelf
1.
Attach the rubber feet to the back of the AP (callout 7 on page 1), and
place the AP back-side down on the table or shelf.
2.
Connect an Ethernet cable to the AP.
3.
Connect the other end of the Ethernet cable to a PoE-capable device, such
as an Ethernet switch.
3
Mounting on a wall
1.
Hold the mounting bracket with the narrow end facing up, against the wall
where you want to install the AP. Mark the location of the three screw
holes.
3
1
2
1: Hook
2: Screw hole
2.
Drill three holes for the wall anchors, typically 5 mm (3/16 inch) in
diameter.
3.
Insert the anchors and tap them flush with the wall surface.
4.
Use the mounting screws to attach the mounting bracket to the wall.
Proceed to Attach the AP on page 5.
Mounting on a suspended ceiling
The AP can be mounted on a suspended ceiling using a T-rail holder.
Note:
The width of the T-rail must be between 16 mm (0.63 inches) and 28
mm (1.10 inches).
Selecting the installation site
Ø5.0
4
86.0
136.0
3: Clip
4: T-rail hook cut-out