Installation - HP MSM430 Quick Start Manual

802.11n access points
Hide thumbs Also See for MSM430:
Table of Contents

Advertisement

HP MSM430, MSM460, MSM466 Dual Radio 802.11n Access Points Quickstart
If the AP will be powered by a user-supplied PoE power injector,
Caution:
use only a gigabit-compatible power injector. Although 10/100 PoE-enabled
switches are compatible, PoE injectors designed for 10/100 networks only are
not compatible with the AP.

Installation

The AP can be mounted on a wall, a wall-mounted electrical box, or a
suspended ceiling. The AP Bracket is mounted first and then the AP is attached
to the bracket. The AP Bracket is two-sided: The AP is installed on the side
with the UP arrow. The other side with the T-bar clip screw holes faces the wall
or T-bar.
Mounting directly on a wall
1.
Hold the AP bracket with the UP arrow pointing up against the wall where
you want to install it. Mark the location of the screw holes (1) [or 5] and
the cutout area (6).
AP Bracket (AP side left, wall/
ceiling side right)
1: Adapter Bracket mounting holes
2: AP Bracket latch
3: Electrical box mounting holes
4: AP retention tabs
5: Drywall mounting holes
6: Cutout area
7: AP Bracket lock tab
8: T-bar clip screw holes
3
2.
Drill two holes for the wall anchors, typically 4.7 mm (3/16 inch) in
diameter.
3.
If necessary, drill a hole for the Ethernet cable in the marked cutout area
of the AP Bracket. Alternatively, you can feed the Ethernet cable from
above and through the AP cable channel.
4.
Insert the anchors and tap them flush with the wall surface.
5.
Pull the Ethernet cable through the hole in the wall and the AP Bracket.
6.
Use the mounting screws to attach the AP Bracket to the wall. Proceed to
Attach the AP on page 4.
Mounting on an electrical box
1.
Disconnect power and take any other needed security precautions.
2.
Remove the electrical box cover and any contents.
3.
Pull the Ethernet cable into the box and through the hole in the AP
Bracket.
4.
Hold the AP Bracket against the box orienting the UP arrow, and attach
the AP Bracket to the box using the countersunk screws. Proceed to
Attach the AP on page 4.
Mounting on a suspended ceiling
The AP can be mounted on a suspended ceiling using T-bar clips. Two sets of
T-bar clips are provided, a 12.5 mm set for recessed tiles and a 4.5 mm set for
flush-mount tiles.
T-bar clips for ceiling mount
1: AP Bracket
2: Recessed tile 12.5 mm T-bar clip
Installation
3: Flat tile 4.5 mm T-bar clip
4: AP Bracket T-bar slot

Hide quick links: