Custom Panels - Sub-Zero ICBIW-18 Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
INSTALLATION
Alignment
DEPTH ADJUSTMENT
Adjust the depth of the unit to fit flush with surrounding
cabinetry. Follow these steps for a precision fit:
Place decorative panel on a protected work surface.
1
Place the panel thickness gauge next to the panel to
determine which notch corresponds with the panel thick-
ness. Refer to the illustration below. Once the proper
notch has been determined, mark that notch with a
marker.
With the door closed, position the top of the unit using
2
the panel thickness gauge. Refer to the illustration
below. Insert a #8 x 13 mm stainless steel screw above
the hinge, then insert a #8 x 13 mm pan head screw on
the handle side of the unit. For narrower units, the door
may need to be opened to access the handle side screw
location. Repeat the process to align the bottom.
ANCHORING
Once the top and bottom are aligned, verify the door/
drawers open properly, then install remaining screws in each
side trim.
SCREW
SIDE TRIM
CABINETRY
FACE
FRAME
FRONT OF
UNIT
PANEL THICKNESS
GAUGE
Panel thickness.
Unit depth.
PANEL INSTALLATION

Custom Panels

Custom door/drawer panels and handle hardware must
be installed. Stainless steel panels are available through an
authorized Sub-Zero dealer.
The thickness of the custom panel can vary. A minimum
16 mm thick panel is required, but the thickness can be
increased provided it does not exceed the maximum panel
weight indicated in the chart below. The depth of each
model is 610 mm. Allow for panel thickness when planning
the finished opening depth.
PANEL REQUIREMENTS
PANEL WEIGHT
Door
Door (ICBIW-30R)
Drawer
PANEL THICKNESS
All Panels
Reveals between panels can vary, 3 mm reveals are typical.
CAUTION
When installing a panel thicker than 25 mm, the 90°
stop may be required to prevent damage to the unit
and adjacent cabinetry.
CAUTION
As reveals between cabinetry and the unit decrease,
severe finger pinching can occur while door is closing.
Finish all sides of custom panels. They will be visible when
the door is open.
D-style handles are recommended. Stainless steel tubular
and pro handles are avail able through an authorized
Sub-Zero dealer. Door handles must be located near the
edge of the panel opposite the hinge and should be cen-
tered top to bottom. Drawer handles must be located near
the top edge of each panel.
DOOR PANEL HEIGHT
The height of the custom door panel can extend beyond the
typical panel height, provided it does not exceed the weight
limit. Refer to the illustration below.
45
mm
3 mm
MAX
16 kg
11 kg
DOOR
7 kg
PANEL
MIN
2134
16 mm
mm
HINGE
Upper valance—side view.
TOE KICK CLEARANCE
The height of the toe kick area can extend beyond the
typical toe kick height, provided it does not exceed the
dimensions in the illustration below. Toe kick heights from
51 mm to 98 mm require a reduced toe kick accessory
available through an authorized Sub-Zero dealer.
A DECORATIVE VALANCE
CANNOT EXTEND
BEYOND THIS PLANE
HINGE
610 mm
DOOR
TO BACK OF UNIT
PANEL
51 mm*
TO
152 mm
FROM
FLOOR
*51 mm to 98 mm requires sales accessory.
Toe kick—side view.
VENTED
LOUVERS
610 mm
TO BACK OF UNIT
29 mm
MAX
TOE KICK
ADJUSTMENT
A DECORATIVE TOE KICK
CANNOT EXTEND
BEYOND THIS PLANE
|
subzero.com
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icbiw-30Icbiw-24Icbiw-30r

Table of Contents