I — INTRODUCTION
SCOPE OF MANUAL. This instruction manual covers
the installation and operation of the Kepco JBW 15W
Series of RoHS (Reduction of Hazardous Substances)
compliant Switching Power Supplies.
DESCRIPTION. The Kepco JBW 15W Series consists of
four models of switching power supplies, with a single out-
put as shown in Table 1. Units may be operated with a
nominal 100 to 120V a-c and 220 to 240V a-c (input voltage
range 85 to 265 Va-c), 50-60 Hz (input frequency range 47-
440Hz.)
They will also operate on 110V to 370V d-c input.
The JBW 15W Series employs a light weight ferrite core
with a variable switching frequency. Regulation is provided
by pulse width modulation. A FET power stage, operating in
MODEL
OUTPUT VOLTS, d-c
SETTING TOLERANCE
ADJUSTMENT RANGE
MAXIMUM
50° C amb.
OUTPUT
60° C amb.
RATINGS
OUTPUT CURRENT (AMPS)
CURRENT LIMIT (AMPS)
OVP RANGE (VOLTS)
100 Va-c
EFFI-
CIENCY
240 Va-c
OUTPUT CAPACITOR
µFmax., (fixed load resistance)
ripple (typ)
ripple
RIPPLE
-10-0°C, max
AND
(1)
spike noise
NOISE
(mV p-p)
(max)
spike noise
-10-0°C, max
(1)
0 to 100% load, 0 to 50 °C, tested with 100µF electrolytic and 0.1µF film capacitors across the measuring points, connected to the power supply
via 5.9 in (150mm) wires; Measured with a 20 MHz bandwidth oscilloscope.

INPUT CHARACTERISTICS:

INPUT VOLTAGE: (0 to 100% load, -10 to 60°C)
Nominal 100-120V a-c, 220-240V a-c
Range: 85-265V a-c, 110 -370V d-c
INPUT SOURCE FREQUENCY:
Nominal 50/60 Hz;
Range 47-440 Hz
KEPCO, INC.
131-38 SANFORD AVENUE
©2010, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
15 WATT SINGLE OUTPUT
SWITCHING POWER SUPPLIES
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, JBW 15W SERIES
JBW 05-3R0
5V
4.75-5.25V
FIXED
3.0A/15W
2.1A/10.5W
3.0
3.15 min
5.75 min
72%
72%
10000
80
140
120
160
FLUSHING, NY. 11355 U.S.A.
http://www.kepcopower.com
the ringing choke converter mode provides a smooth iso-
lated d-c output. A thermistor circuit prevents excessive
turn-on current surge. Overvoltage protection is provided.
Current limiting with automatic recovery from short circuit is
featured. Units are manufactured on an open frame pc
board.
Table 1 contains specifications and operating limits of indi-
vidual JBW 15W Series models. Section II (following) con-
tains specifications and operating limits common to all JBW
15W Series Models.
II — SPECIFICATIONS
The following specifications are at nominal input voltages at
25°C unless otherwise specified.
JBW 12-1R3
JBW 15-1R0
12V
11.4-12.6V
14.25-15.75V
FIXED
1.3A/15.6W
0.9A/10.92W
1.3
1.37 min
13.8 min
76%
74%
5000
120
160
150
180
INPUT CURRENT: (100% load at 25°C with nominal out-
put voltage):
100V a-c input:
240V a-c input:
INPUT PROTECTION AND SOFT START: A
tor circuit reduces start-up surge. Units are protected
against shorts by an input fuse. Fuse value 2.0A, 250V.
TEL (718) 461-7000
email: hq@kepcopower.com
228-1413 REV 5
JBW
15W SERIES
JBW 24-0R7
15V
FIXED
1.0A/15.0W
0.7A/10.5W
0.49A/11.76W
1.0
1.05 min
17.25 min
76%
74%
4000
120
160
150
180
0.36 typ., 0.43 max.
0.20A typ., 0.24A max.
FAX (718) 767-1102
24V
22.8-25.2V
FIXED
0.7A/16.8W
0.7
0.74 min
27.6 min
78%
76%
2000
120
160
150
180
thermis-
1

Advertisement

loading

Summary of Contents for KEPCO JBW 05-3R0

  • Page 1: Input Characteristics

    A thermistor circuit prevents excessive SCOPE OF MANUAL. This instruction manual covers turn-on current surge. Overvoltage protection is provided. the installation and operation of the Kepco JBW 15W Current limiting with automatic recovery from short circuit is Series of RoHS (Reduction of Hazardous Substances) featured.
  • Page 2 INCOMING NOISE: 1 µs, 2 KV pulse, 50-60Hz, with 50 ohm termination, input to input, input to ground, less than five minutes, operating. WARRANTY: One year. KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102 http://www.kepcopower.com...
  • Page 3 AC input Neutral and Line wires to the P2 and P3 pins respectively of TB1 (see Figure 3). A Cable Kit (P/N 219- 0406) is available as an option from Kepco (see Figures 3 and 5). The kit includes an input cable, terminated on one end with an input mating connector;...
  • Page 4 (4) Optional cable kit (P/N 219-0406) includes one input and one output cable (one meter long) with mating connectors for TB1 and TB2, unterminated at other end. FIGURE 5. INPUT/OUTPUT CONNECTIONS KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102 http://www.kepcopower.com...

This manual is also suitable for:

Jbw 15-1r0Jbw 12-1r3Jbw 24-0r7