I — INTRODUCTION
SCOPE OF MANUAL. This instruction manual covers
the installation and operation of the Kepco JBW 100W
Series of RoHS (Reduction of Hazardous Substances)
compliant Switching Power Supplies.
DESCRIPTION. The Kepco JBW 100W Series consists
of four models of switching power supplies, each with a sin-
gle output as shown in Table 1. Units may be operated with
a nominal 100 to 120V a-c and 220 to 240V a-c (input volt-
age range 85 to 265 Va-c), 50-60 Hz (input frequency
range 47-440Hz.)
They will also operate on 120V to 370V
d-c input. The JBW 100W Series employs a light weight fer-
rite core. Regulation is provided by pulse width modulation.
Power Factor Correction (PFC) is provided by a boost con-
verter operating at 80kHz. A FET power stage, operating
as a forward converter with a fixed switching frequency of
OUTPUT VOLTS, d-c
ADJUSTMENT RANGE
CURRENT/MAX. POWER RATINGS
OVERCURRENT (AMPS)
OVP RANGE (VOLTS)
EFFICIENCY (typ.)
ACCEPTABLE EXTERNAL OUTPUT CAPACITOR
µFmax., (fixed load resistance)
RIPPLE AND
(2)
NOISE
(mV p-p)
(1)
5.0A peak, t
(2)
0 to 100% load, 0 to 60 °C, tested with 100µF electrolytic and 0.1µF film capacitors across the measuring points, connected to the
power supply via 5.9 in (150mm) wires; oscilloscope bandwidth

INPUT CHARACTERISTICS:

INPUT VOLTAGE: (0 to 100% load, -10 to 60°C)
Nominal 100-120V a-c, 220-240V a-c
Range: 85-265V a-c, 120 -370V d-c
NOTE: The power supply may shut down if operated at
below the input voltage range or if the input voltage
increases slowly at start up (> 1 second). To reset the
power supply, unplug the unit, wait one minute and
reapply input power.
INPUT SOURCE FREQUENCY:
Nominal 50/60 Hz;
Range 47-66 Hz (Above 66Hz to 440 Hz the leakage
current may exceed the VDE safety specification limit.)
KEPCO, INC.
131-38 SANFORD AVENUE
©2010, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
100 WATT SINGLE OUTPUT
SWITCHING POWER SUPPLIES
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, JBW 100W SERIES
MODEL
100 Va-c
240 Va-c
ripple (typ)
°C)
ripple (typ) (-10 to 0
spike noise (typ)
spike noise (typ)
°C)
(-10 to 0
10 seconds, not to exceed 4.3A rms, output power
http://www.kepcopower.com
150kHz provides a smooth isolated d-c output. A thermistor
circuit prevents excessive turn-on current surge. Overvolt-
age protection is provided. Current limiting with automatic
recovery from short circuit is featured. Units are manufac-
tured on an open frame PC board.
Table 1 contains specifications and operating limits of indi-
vidual JBW 100 Series models. Section II (following) con-
tains specifications and operating limits common to all JBW
75W Series Models
II — SPECIFICATIONS
The following specifications are at nominal input voltages
and 25°C and apply to all models unless otherwise speci-
fied.
JBW 5-20K
JBW 12-8.5K
5V ±0.25V
12V ±0.6V
4.5-5.5V
10.8-13.2V
20.0A/100W
8.5A/102W
21.0 min.
10.6 min.
5.75-6.9
13.8-16.8
78%
80%
80%
82%
30,000
30,000
80
120
140
160
120
150
160
180
100W.
20MHz.
INPUT CURRENT: (100% load at 25°C with nominal out-
put voltage):
100V a-c input:
240V a-c input:
INPUT PROTECTION AND SOFT START: A
tor circuit reduces start-up surge. Units are protected
against shorts by an input fuse. Fuse value 5A, 250V.
INPUT SURGE: Cold start:
100V a-c input, 100% load: 15A typ., 30.0A max.
240V a-c input, 100% load: 30A typ., 60.0A max.
FLUSHING, NY. 11355 U.S.A.
email: hq@kepcopower.com
228-1552 REV 2
JBW
100W SERIES
JBW 15-6.7K
15V ±0.75V
13.5-16.5V
6.7A/100.5W
8.38 min.
17.2-21.0
80%
82%
30,000
120
160
150
180
1.3A typ., 1.8A max.
0.6A typ., 1.0A max.
TEL (718) 461-7000
FAX (718) 767-1102
JBW 24-4.3K
24V ±1.2V
21.6-26.4V
(1)
4.3A
/103.2W
5.38 min
27.6-33.6
82%
85%
30,000
120
160
150
180
thermis-
1

Advertisement

loading

Summary of Contents for KEPCO JBW 5-20K

  • Page 1: Input Characteristics

    I — INTRODUCTION SCOPE OF MANUAL. This instruction manual covers 150kHz provides a smooth isolated d-c output. A thermistor the installation and operation of the Kepco JBW 100W circuit prevents excessive turn-on current surge. Overvolt- Series of RoHS (Reduction of Hazardous Substances) age protection is provided.
  • Page 2 WARRANTY: One year. lation to deteriorate. ORIENTATION: Vertical or horizontal (see Figure 2). KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102 http://www.kepcopower.com...
  • Page 3 3 and 1, respectively, of CON1. See Figure 5 for mating connector information. A Cable Kit (P/N 219- 0495) is available as an option from Kepco. The kit includes one input and one output cable (one meter long) FIGURE 3.
  • Page 4 (one meter long) with mating connectors for Input and Output connector, unterminated at other end. FIGURE 5. INPUT/OUTPUT CONNECTIONS KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102 http://www.kepcopower.com...