LEVELINg THE TABLE
To reduce the risk of injury, turn unit off
and disconnect it from power source before installing
and removing accessories, before adjusting or when
making repairs. An accidental start-up can cause injury.
To make the table parallel to the cutterhead knives:
1. Remove the four screws that attach the top cover to
the planer. Carefully remove the top cover.
2. Place a straight edge (A) Fig. 21 on the surfaces.
3. Place the gauge block (C) Fig. 21 on the table
directly beneath the straight edge at one side. Raise
the table until the gauge block barely touches the straight edge. Do not raise or lower the table any farther until
the adjustment is complete.
4. Move the gauge block (C) Fig. 21 to the opposite (left end) of the table and see if the table is the same distance
from the straight edge as on the right side.
5. Place the straight edge (A) on the two surfaces of the outfeed end of the planer (Fig. 22). Check both ends of the
table with the gauge block (C) to see if the table is level.
6. If the table is not level, locate the post to be adjusted directly beneath the table. Loosen the three screws - two of
which are shown at (A) Fig. 23. Turn the flange (B) to raise or lower the table at that end.
CHECkINg AND ADJUSTINg BED ROLLER HEIgHT
To set the height of the bed rollers (A) and (E) Fig. 24 between .002" and .004" above the table surface with the bed
rollers at their lowest position:
To reduce the risk of injury, turn unit off and disconnect it from power source before installing and remov-
ing accessories, before adjusting or when making repairs. An accidental start-up can cause injury.
1. Turn the height-adjustment knob (B) Fig. 24 counter-clockwise as far as it will go.
2. Place a straight edge (C) across the infeed and outfeed rollers on the left side of the table.
3. Use a feeler gauge (D) to measure the gap between the table surface and the straight edge (C) near the infeed roll (E).
4. To adjust, loosen the set screw (F) Fig. 25, located underneath the left front end of the table.
5. Turn the adjustment collar (G) Fig. 25 left or right as needed to attain proper height adjustment.
6. Tighten the set screw (F) Fig. 25 after adjusting.
C
D
B
A
C
Fig. 22
Fig. 24
E
A
Fig. 25
F
14
A
C
Fig. 21
B
A
Fig. 23
g