TROUBLESHOOTING
Park Brake Alarm Fails to Turn Off
Possible Cause
Park brake is not completely disengaged
Park brake connector malfunction or switch move-
ment or failure
Engine Doesn't Turn Over
Possible Cause
Low battery voltage
Loose battery connections
Loose solenoid connections
Loose electronic control box connections
Engine Turns Over, Fails to Start
Possible Cause
Out of fuel
Clogged fuel filter/water separator
Clogged air filter
Water is present in fuel
Old or non-recommended fuel
Water or fuel in crankcase
Low battery voltage
Mechanical failure
Defective glow plug
Defective stop solenoid
Defective fuel pump
Engine Backfires
Possible Cause
Old or non-recommended fuel
Loose ignition connections
Water present in fuel
82
Solution
Ensure lever is in forward-most position
Disconnect the connector if temporary continued
operation is necessary, see your dealer promptly for
service
Solution
Recharge the battery to 12.8 VDC
Check all connections and tighten
Check all connections and tighten
Inspect, clean, reinstall connectors
Solution
Refuel
Replace
Replace
Drain the fuel system and refuel, replace fuel filter/
water separator
Replace with fresh recommended fuel
Immediately see your POLARIS dealer
Recharge the battery to 12.8 VDC
See your dealer
Inspect and replace
Replace
Replace
Solution
Replace with fresh recommended fuel
Check all connections and tighten
Replace with fresh recommended fuel