To install the switch in a rack, follow these steps:
1. Attach the mounting brackets to the sides of the switch as illustrated in Figure 3-1.
Hold a mounting bracket against each side of the switch and align the countersunk screw holes in
the bracket with the bracket mounting holes in the switch.
2. Insert the screws provided with the mounting brackets through each bracket and into the
bracket mounting holes in the switch.
3. Using a #1 Philips screwdriver, tighten the screws to secure each bracket.
4. Hold the switch with the mounting holes in the brackets aligned with the holes in the rack.
Figure 3-1. Attaching mounting brackets to the Model SW502 and Model SW507 switches
5. Insert two pan-head screws with nylon washers through each bracket and into the rack.
6. Using a #2 Philips screwdriver, tighten the screws to secure the switch to the rack.
7. Install any additional devices in your stack.
For proper ventilation, make sure that the switch has at least two inches of space on each side and
five inches of space on the back side. It is very important that the fans located in the rear panel are
not blocked. Restricted airflow could cause overheating of the components.
For instructions on connecting to additional switches or other devices, refer to "Connecting
Devices to the Switch."
Installation
Installation Guide for the Model SW502 and Model SW507 Ethernet Switches
3-3