Diagnostics Push Button - NETGEAR SW502 Installation Manual

Table of Contents

Advertisement

Table 2-2. Port status LEDs
Label
Color
Collision
Orange
Transmit
Green
Receive
Green
Link
Green
100M
Green

Diagnostics Push Button

The Diagnostics push button initiates the self-diagnostics test to determine the status of the system
components of the switch. The diagnostic test will automatically start when the system is powered on.
To start the diagnostic test after the switch has started operation, press the Diagnostics push button for
two seconds and then release.
After the self-diagnostic test starts, it will continue until all of the components of the ports are tested.
On completion of the diagnostic testing process, the LEDs will continue to blink (refer to Table 2-3).
This blinking indicates the corresponding port components that have failed. The blinking will
continue until the failed port has been repaired.
Table 2-3. Port Diagnostic Test
LED Label
Color
Collision
Orange
Transmit
Green
Receive
Green
Link
Green
Physical Description
Activity
Function
Blinking light
Indicates collision during packet transmission on the port.
Blinking light
Indicates packet transmission on the port.
Blinking light
Indicates packets are being received on the port.
Steady light
Indicates a valid link is established on this port.
Light off
No valid link is established on this port. For troubleshooting
procedures, refer to Appendix D, "Troubleshooting."
Steady light
Port is operating at 100 Mbps.
Light off
Port is operating at 10 Mbps.
Activity
Blinking light
Blinking light
Blinking light
Blinking light
Using the Model SW502 and SW507 Ethernet Switches
Diagnostic Display Mode
Failed port I.C. test.
Failed output queue RAM test.
Failed input queue RAM test.
Failed routing table RAM test.
For troubleshooting procedures,
refer to Appendix D, "Troubleshooting."