Connection
•
Set the power switch of the electrical device that is to be connected to the receiver
to OFF.
•
Connect the electrical device to the receiver before it is connected to a power point.
•
Turn the devices on by setting their power switches to ON, I etc.
Specifications
Voltage
230 VAC, 50 Hz, 16 A
3680 W (resistive load),
Max power
150 W (inductive load, e.g. fluorescent lamp)
Protection class IP20
Frequency
433.92 MHz
Range
Up to 70 metres (unobstructed)
Note:
•
Other wireless equipment using the same frequency can reduce
the transmission range.
•
The range of all wireless equipment depends on the type of obstacles located
between the transmitter and the receiver (e.g. a concrete wall will interfere with
the signal more than a plasterboard wall).
If you experience problems, try the following:
•
Turn off any existing wireless equipment to see if that could be causing
the problem.
•
Move the wireless equipment and/or shorten the distance and reduce
the number of obstacles (walls, furniture, etc) between the transmitter
and receiver.
6