2. BEFORE INSTALLATION

• When moving the unit while removing it from the carton box, be sure to lift it by holding on to the
four lifting lugs without exerting any pressure on other parts, especially swing flap, the refrigerant
piping, drain piping, and other resin parts.
• Be sure to check the type of refrigerant to be used before installing the unit. (Using an incorrect refrigerant
will prevent normal operation of the unit.)
• The accessories needed for installation must be retained in your custody until the installation work is com-
pleted. Do not discard them!
• Decide upon a line of transport.
• Leave the unit inside its packaging while moving, until reaching the installation site. Where unpacking is
unavoidable, use a sling of soft material or protective plates together with a rope when lifting, to avoid dam-
age or scratches to the unit.
• When selecting installation site, refer to the paper pattern.
• For the installation of an outdoor unit, refer to the installation manual attached to the outdoor unit.
• Do not use the unit in locations with high salt content in the air such as beachfront property, locations where
the voltage fluctuates such as factories, or in automobiles or marine vessels.
2-1 ACCESSORIES
Check the following accessories are included with your unit.
Name
1) Drain hose
Quan-
1 pc.
tity
Shape
Name Insulation for fitting
Quan-
1 each.
tity
6) For gas pipe
Shape
7) For liquid pipe
2-2 OPTIONAL ACCESSORIES
• The remote controller are required for this indoor unit "Table 1" on page 3.
(However, the remote controller is not required for the slave unit of a simultaneous operation system.)
• These are two types of remote controllers: wired and wireless. Select a remote controller from
"Table 1" on page 3 according to customer request and install in an appropriate place.
Table 1
Remote controller type
Wired type
Wireless type
English
3) Washer for
2) Clamp
hanger bracket
1 pc.
8 pcs.
Sealing pad
1 each.
8) Large
9) Small
Cooling only type
BRC7EA66
4) Clamp
6 pcs.
(Other)
Operation manual
Installation manual
Heat pump type
BRC1D528, BRC1C61
5) Paper pattern
for installation
1 pc.
BRC7EA63W