Indoor Unit Installation
3.

Installing interunit wiring

1) Remove the service lid from the front grill.
2) Take off the electric parts box service lid.
3) After attaching the mounting plate, connect the interunit wiring as shown
in the figure at right.
4.
Laying piping, hoses, and wiring
• Lay the piping and drain hose according to the orientation of the piping
coming out of the unit, as shown below.
• Make sure the drain hose is sloped downward.
• Wrap the piping and the drain hose using insulating tape.
• Bind and then shape the pipes, hoses, and wires so that they can fit through
the piping through-hole.
• When cutting out the piping through-hole, cut out Part A using nippers along
the cut-out groove as shown in the figure at right.
Stopping the nippers part-way through Part A may cause it to break.
4-1. Right-Side, Right-Back, or Right-Bottom Piping
1) Attach the drain hose to the underside of the refrigerant pipes with
adhesive vinyl tape.
2) Wrap the refrigerant pipes and drain hose together with insulation tape.
3) Put all the pipes through the through-hole in the wall and attach the
indoor unit to the mounting plate.
(See p5 Installing and removing the indoor unit)
4) Connect the pipes.
5) Store any excess power cord behind the indoor unit.
6) Making sure not to pinch the interunit wiring and the power cord, push
on the bottom of the indoor unit with both hands and attach the tabs.
If the indoor unit won't attach to the mounting plate, fix the bottom
panel to the mounting plate with screws. (In one place on the left side
or the right side.)
4-2. Left-Side, Left-Back, or Left-Bottom Piping
1) Attach the drain hose to the underside of the refrigerant pipes with
adhesive vinyl tape.
2) Be sure to connect the drain hose to the drain port in place of a drain
plug.
1. Pull out the drain plug.
2. Pull out the drain hose and reattach it on the left side.
3. Reattach the drain plug on the right side.
3) Pull in the refrigerant piping and lay it so that it matches the
liquid and gas piping marked on the mounting plate.
4) Attach the indoor unit to the mounting plate.
5) Connect the pipes. If it is difficult to do, remove the front grill
first.
7
Interunit wiring
Service lid
2=HJ )
2=HJ )
Remove pipe port
cover here for
Right-bottom
right-side piping
piping
Remove pipe port cover
here for right-bottom piping
Make sure the power cord does not
enter the area marked with
If the cord enters that area, there
exists a danger that the drain might
leak onto the power cord.
If there is any
leftover space for
the piping, store
the cord in there.
Remove pipe port cover here for
left-bottom piping
0
ow to set drain plug
Insert a hexagon wrench (4mm)
Drain hose
Caulk this hole
with putty or
Bind with plastic tape.
caulking material.
Interconnecting wires
Attach the
indoor unit
hooks.
Lift the indoor unit slightly
by placing it on packing or
other similar materials.
Right-back piping
Bind coolant pipe
and drain hose
together with
insulating tape.
.
Make sure the power
cord does not get
pinched on the bottom
frame tabs.
Remove pipe
port cover
here for left-
side piping
Left-side
piping
Left-back
piping
Left-bottom
piping
Do not apply lubricating
oil (refrigerant machine
oil) when inserting
Application of causes
deterioration and drain
leakage of the plug
A Mounting plate
Wrap insulating tape
around the bent portion
of refrigerant pipe.
Overlap at least half the
width of the tape with
each turn.
IEnglish