Heat-N-Glo 6000 TRI Installer's Manual page 27

Table of Contents

Advertisement

TRANSFORMER OUTLET
PLUG-IN
3V TRANSFORMER
LOW VOLTAGE
SEE NOTE 1
IGNITION
MODULE
(3V)
ON/OFF
WALL SWITCH
VALVE
GROUND
NEUTRAL
Figure 40. Intermittent Pilot Ignition (IPI) Wiring Diagram
Intermittent Pilot Ignition (IPI) Wiring
3 Volt Transformer
This appliance comes with a 3 volt transformer found in the
manual bag. Plug the transformer leads to the green con-
trol module (see Figure 40). Then plug the transformer into
the side outlet on the junction box.
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
factory installed junction box. Maintain correct polarity when
wiring the junction box.
WARNING: DO NOT CONNECT 1 10-120 V AC
!
TO THE GAS CONTROL VALVE OR THE AP-
PLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED.
Optional Accessories
Optional remote control kits require that 110-120 VAC be
wired to the factory installed junction box before the fire-
place is permanently installed.
Operation using Battery Power
This fireplace has an optional battery operation. The sys-
tem is fully functional with the use of two "D" size batteries
without ordinary 110-120 VAC power.
TRANSFORMER
3V
FLAME SPARKER /
SENSOR
OPTIONAL
BATTERY
BACK-UP
ON/OFF
SWITCH
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL
HOT
NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts.
120 VAC is required at junction box unless equipped with battery back-up.
120 VAC
JUNCTION BOX
IGNITOR
MODULE
REM
FAN
BLACK
OPTIONAL
BATTERY
BACK-UP
RED
BROWN
BROWN
Wiring to the battery pack should be left disconnected in
order to conserve battery life. In the case of a loss of power,
simply connect red and black wire leads to activate battery
power (connect red to red, black to black). The fireplace
can be used as necessary. Once power (110 VAC) is re-
stored, disconnect red and black wire leads to extend bat-
tery life.
Wall Switch
Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.
WARNING: DO NOT CONNECT 1 10-120 VAC
!
TO THE W ALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.
29
SPARK TO
PILOT IGNITOR
3V
BLACK (IGNITOR)
BLACK (SENSOR)
BLACK
PILOT ASSEMBLY
AND VALVE ASSEMBLY
MUST BE GROUNDED
GROUND TO
(COMMON GROUND
FIREPLACE
WITH FIREPLACE
CHASSIS
CHASSIS)
ORANGE
GREEN

Advertisement

Table of Contents
loading

Table of Contents