Instal lation
4.8

Gas installation

WARNING!
The gas connection shall be carried out
by specialised personnel* only.
* Specialised personnel are accredited experts who are
able, by virtue of their training and knowledge, to vouch
for the correct installation and implementation of the lea-
kage test.
n
Observe the regulations stated in sec-
tion 4.1 .
n
This refrigerator is provided for installa-
tion within Universal gas equipment and
must be run exclusively on liquid gas (no
natural gas, town gas).
n
An AGA Approved LP Regulator must be
fitted to the gas supply. The pressure
regulator must concur with the opera-
ting pressure specified on the rating
plate of the appliance. The operating
pressure corresponds to the standad
pressure of the country of specification.
n
Only one connection pressure is permis-
sible for any one vehicle! A plate sho-
wing the permanent, clearly legible noti-
ce must be displayed in full view at the
point where the gas cylinder is installed.
n
The gas connection to the appliance
must be installed securely and free of
stress using pipe connectors and must
be securely connected to the vehicle .
n
The gas connection to the appliance is
1/8"BSP Female (s. figure 31).
n
The refrigerator must be equipped with a
gas cock in the supply line to allow the
supply to be disconnected. Such a cut-
out device must be readily accessible to
the user.
Gas connection
CAUTION!
Observer maximum torque!
10 Nm
max
Testing point
1
2
Adapter (DO NOT LOOSEN!)
Connection to gas supply
3
Gas pressure
Refer to data label.
Before Leaving - Check all connections for
gas leaks with soap and water. DO NOT use
an unshielded flame for detecting leaks. Ignite
the burner to ensure correct operation of gas
valve, burner and ignition. When satisfied with
the appliance, please instruct the user on the
correct method of operation.
appliance fails to operate correctly after all
checks have been carried out, refer to the aut-
horised service provider in your area.