Thd Spectrum At 10 Khz - Benchmark PRE420 Instruction Manual

4-channel microphone preamplifier/mixer
Table of Contents

Advertisement

THD Spectrum at 10 KHz

Audio Precision
dx=10.0073 kHz
-100
-102
-104
-106
-108
-109.271
-110
-112
-114
-116
-118
-118.787
-120
-122
d
-124
B
r
-126
A
-128
-130
-132
-134
-136
-138
-140
-142
-144
-146
-148
-150
2k
4k
Sweep
Trace
Color
1
1
Red
The above FFT plot shows that the PRE420 has very little harmonic distortion at high frequencies.
The 10 kHz test tone is notched out with a THD analyzer to improve the resolution of the test. The
nd
20-kHz 2
-harmonic distortion measures better than -109 dB. The 30-kHz 3
measures better than -118 dB.
PRE420 Instruction Manual – rev. E
10 kHz FFT at 60 dB Gain, Output Level = +24 dBu, 0 dBr = +24 dBu
dy=-9.515 dB
6k
8k
10k
12k
Line Style
Thick
Data
Solid
4
Fft.Ch.2 Ampl
20.022k
14k
16k
18k
Hz
Axis
Comment
Cursor1
Left
*-109.271 dBr A
20k
22k
24k
26k
Cursor2
*-118.787 dBr A
rd
-harmonic distortion
02/19/07 11:09:30
30.0293k
28k
30k
32k
Page 25

Advertisement

Table of Contents
loading