Dimensional Drawings - Daikin FH35GZ Technical Data Manual

Table of Contents

Advertisement

3

Dimensional drawings

FH45BZV1
Note:
1. Location of unit's name plate: bottom of fan housing inside the
suction grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
10
3. The remote control code is the standard (about 3m outside the
machine) attached.
2
x 2 Wicks x O.D. J5.4)
(0.5 mm
(It is not attached in VRV.)
3
FH60BZV1
Obstacle
Note:
1. Location of unit's name plate: bottom of fan housing inside the
suction grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the
machine) attached.
2
x 2 Wicks x O.D. J5.4)
(0.5 mm
(It is not attached in VRV.)
10
• Ceiling Suspended Unit • R-407C • FH(Y)-GZ/BZ/FHYP-B
Hanging bolt
30 or more
(Service space)
Obstacle
Floor side
Drain pipe connection
VP20
(For left piping)
Hanging bolt
30 or more
(Service space)
Floor side
Drain pipe connection
VP20
(For left piping)
• Split - Sky Air • Indoor Units
(Hanging position)
30 or more
(Service space)
View from the front
Brand name plate
(Note 2)
(Hanging position)
30 or more
(Service space)
View from the front
Brand name plate
(Note 2)
Position slit hole for taking out in piping back
(View from the front)
Position: hole of wall for taking out in piping back
(View from the front)
1
Air discharge grille
2
Air suction grille
3
Air filter
Gas pipe connection J15.9 flare
4
Liquid pipe connection J6.4 flare
5
6
Drain pipe connection VP20
7
Earth terminal (inside the electric components box) M4
8
Suspension bracket
9
Backward piping and wiring connection opening lid
10
Upward piping and wiring connection opening lid
11
Right side pipe connection - slit hole
12
Left back drain pipe connection - slit hole
13
Right side drain pipe connection - slit hole
14
Right side drain piping connection hole- slit hole
Hole of wall for taking out in piping back J100
15
Upward drain pipe connection J60
16
Upward gas pipe connection J36
17
Upward liquid pipe connection J26
18
Position slit hole for taking out in piping back
(View from the front)
Position: hole of wall for taking out in piping
back
(View from the front)
1
Air discharge grille
2
Air suction grille
3
Air filter
Gas pipe connection J15.9 flare
4
Liquid pipe connection J6.4 flare
5
6
Drain pipe connection VP20
7
Earth terminal (inside the electric components box) M4
8
Suspension bracket
9
Backward piping and wiring connection opening lid
10
Upward piping and wiring connection opening lid
11
Right side pipe connection - slit hole
12
Left back drain pipe connection - slit hole
13
Right side drain pipe connection - slit hole
14
Right side drain piping connection hole- slit hole
Hole of wall for taking out in piping back J100
15
Upward drain pipe connection J60
16
Upward gas pipe connection J36
17
Upward liquid pipe connection J26
18
3D028600
3D027537