Quick Connect Coupling - Type II –
Connect
1. Inspect for damage and clean fittings.
CAUTION: Make sure the fuel tube clicks into
place when installing the tube. To make sure
that the fuel tube is fully seated, pull on the
tube.
2. Lubricate the o-ring seals with clean
engine oil.
3. Release the locking tab and install the
quick connect coupling onto the fitting.
4. Position the locking tab into the latched
position.
5. Pull on the fitting to make sure it is fully
engaged.
TSG‐416 FUEL SYSTEM 
04 ‐ 24 