Optical Adjustment
2. PBS adjustment
1
Select the internal test pattern signal "All white" from the projector's menu "Menu -> Setting -> Test pattern".
2
Loosen screws-A on the integrator-out unit.
3
Insert a slot screwdriver into the slot-B and turn it as the brightness on the screen is to be the maximum.
4
A
Tighten screws
to fix the Integrator-out unit.
Fig.5
A
B
-58-