Sanyo PLC-XF1000 Service Manual page 40

Hide thumbs Also See for PLC-XF1000:
Table of Contents

Advertisement

Optical Parts Disassembly
1-1 Polarized glasses-out/pre-polarized glasses removal
Remove 1 screw-B (M.5x4) on each stopper and take the polarized glasses
upward off.
B
(Blue)
Film side
Mounting direction
Mount the pre-polarized glasses and polarized glasses as shown in the figure below.
Lcd panel/Prism top view
Red Marker
R-LCD panel
Green Marker
Black Marker
(Top side)
* Note on handling the polarized glasses
Polarized glass-(OUT/G) is very sensitive parts. Never touch or wipe the both surfaces. Grab the edge of the glass by new
gloves when handling the polarized glass. When removing the dust on the surface, use a commercial (inert gas) air spray to
remove them. Never use organic solvents.
Pre-Polarized glass-(OUT/B)
Polarized glass-(OUT/B)
Film side
B
(Green)
Polarized glass-(OUT/G)*
Polarized glass-(OUT/G)
B
(red)
Polarized glass (OUT/R)
Film side
Film side
Prism
G-LCD panel
-40-
Black Marker
* When removing the outer
Polarized glass-(OUT/G),
remove the inner Polarized
glass-(OUT/G) first.
Otherwise the edge of the
holder may scratch the sur-
face of polarizged glass.
Film side
Pre-Polarized glass (OUT/R)
Blue Marker
B-LCD panel
Film side