Heat-N-Glo BE-41 Installer's Manual page 6

Table of Contents

Advertisement

The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo
disclaims any responsibility for, the following actions:
• Installation of any damaged fireplace or vent system
component.
• Modification of the fireplace or direct vent system.
• Installation other than as instructed by Heat-N-Glo.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not manu-
factured and approved by Heat-N-Glo, not withstanding
any independent testing laboratory or other party approval
of such component part or accessory.
ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE
HAZARD.
GAS LINE
ACCESS
2 1/8
[55mm]
6 7/8 [174mm]
GAS
LINE
ACCESS
Figure 1. Diagram of BE-41
14 ¼
[362mm]
8 5/8 [219mm]
VENT COLLARS
38
[965mm]
41
[1043mm]
TOP STANDOFFS
RATING PLATE
AND LABELS
GAS
CONTROLS
When planning a fireplace installation, it’s necessary to
determine:
• Where the unit is to be installed.
• The vent system configuration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and finishing details.
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
If the fireplace is to be installed on carpeting or tile, or on
any combustible material other than wood flooring, the
fireplace should be installed on a metal or wood panel that
extends the full width and depth of the fireplace.
28 1/2 [724mm]
21 1/2 [548mm]
11 5/8 [297mm]
34 5/8
25 ¼
[879mm]
[642mm]
36 1/8
[916mm]
TOP VENT COLLARS
REAR VENT COLLARS
HOOD
TOP
LOUVER
LOWER
LOUVER
ELECTRICAL
ACCESS
8
ELECTRICAL
[219mm]
ACCESS
COLLARS
24 5/8
3 ½
[625mm]
[90mm]
10 ¼
[259mm]
8 5/8
VENT

Advertisement