I N S T R U C T I O N M A N U A L
KEPCO
HOT SWAP PLUG-IN POWER SUPPLIES
I — INTRODUCTION
The Kepco HSF 150 Watt Series hot swappable, high frequency switching, plug-in power supplies employ forward conversion
and are designed to operate in a fault tolerant power system with either a-c or d-c input. A resistor and thyristor soft-start circuit
limits start-up surge. A built-in forced current share circuit and OR-ing diodes allow configuration for hot-swap and parallel-
redundant N+1 operation.
These power supplies are designed to be used with Kepco's Series RA 19-(X)B rack adapters (Figure 1). The RA 19-8B rack
adapter accepts up to eight 50 Watt or 100 Watt units; RA 19-7B accepts up to four 50 Watt or 100 Watt units and three 150 Watt
units; RA 19-6B accepts up to six 150 Watt units (see Figure 1). All input/output connections are through a 24 pin connector that
plugs in to the rack adapter. All external connections are made through the rack adapter. Surface mount technology permits effi-
cient component layout for minimum mounting space.
Six models may be selected for outputs of 5, 12, 15, 24, 28, or 48V (see Table 1).
When the input is cut off, the output is maintained for 15 milliseconds minimum. If the power supply shuts down due to an output
overvoltage condition, it is then necessary to wait 90 seconds minimum (120V a-c input) or 120 seconds minimum (240V a-c
input) before turning the unit on again. EMI filtering is designed to meet FCC Class B rating and VDE 0871 Class B rating. This
page contains specifications for each model of the HSF 150 Watt Series. Environmental specifications for each model are the
same.
MODEL
OUTPUT VOLTS, d-c (NOMINAL)
ADJUSTMENT RANGE
OUTPUT CURRENT (NOMINAL)
OUTPUT POWER (NOMINAL)
source (typ)
RIPPLE
source (max)
AND
NOISE
switching (typ)
(mV p-p)
0-40°C
switching (max)
10-100% LOAD
spike noise (d-c—50MHz)
OVERVOLTAGE SETTING (25 °C, NOM. INPUT)
OVERCURRENT SETTING (25 °C, NOM. INPUT)
Rectangular type characteristic
(1) Derates same as Ouptut Power.
(2) See power derating curve, Figure 3.
II — FEATURES
FRONT PANEL ACCESS. The front panel provides a power ON/OFF switch controlling input power and a "VDC ON" light
which indicates when the unit is operating. NOTE: The ON/OFF switch must be set to OFF before removing unit from rack
adapter. The front panel "MASTER ON" LED lights when 1) the unit operates independently, or 2) the unit is used in parallel
redundant configurations while a) the output is less than 10% of nominal or b) the output is within 10% to 100% of nominal and
the unit is functioning as a master. In parallel redundant configurations, the module with the highest voltage functions as the
master. The other units are slaves, and track the output voltage of the master. Refer to Current Share Bus (CSB) on page 3 for
details. The front panel Vadj trimmer provides adjustment of the output voltage within the limits specified in Table 1; test points
connected to the +S and –S lines are available at the front panel for measuring the output.
FORCED CURRENT SHARE CIRCUIT. When units are configured for N+1 parallel redundant operation, it is desirable for cur-
rent to be divided equally among the paralleled supplies. When the CSB (Current Share Bus) lines of paralleled HSF units are
connected together, the load current is forced to divide equally between all paralleled units. If one unit fails, the remaining units
will continue to supply the load, and the load current will be divided equally among the remaining operating units. The failed unit
is automatically isolated from the circuit by a built-in isolation diode. Refer to Current Share Bus (CSB) on page 3 for details.
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
©2006, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
KEPCO SINGLE OUTPUT 150 WATT
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF 150W SERIES
HSF 5-30
5V
4.5 - 5.5V
(1)
30A
(2)
150W
10
20
30
60
<120
6.5 - 7.5V
32.0 - 36.0A
http://www.kepcopower.com " email: hq@kepcopower.com
HSF 12-12
HSF 15-10
12V
15V
11.4 - 12.6V
13.5 - 16.5V
12A
10A
144W
150W
15
15
30
40
35
40
70
80
<190
<220
13.7 - 15.7V
17.0 - 19.0V
13.0 - 15.0A
11.0 - 13.0A
228-1301 REV 4
HSF
150W
HSF 24-6
HSF28-5
24V
28V
22.5 - 25.5V
26.5 - 29.5V
6A
5A
144W
140W
15
20
40
40
50
60
110
140
<310
<330
27.0 - 30.5V
32.0 - 35.0
6.3 - 7.5A
5.3 - 6.1A
HSF 48-2.8
48V
45.0 - 51.0
2.8A
134.4W
20
40
80
220
<530
53.5 - 60.0
3.0 - 3.5A
1

Advertisement

loading

Summary of Contents for KEPCO HSF 12-12

  • Page 1 N+1 operation. These power supplies are designed to be used with Kepco’s Series RA 19-(X)B rack adapters (Figure 1). The RA 19-8B rack adapter accepts up to eight 50 Watt or 100 Watt units; RA 19-7B accepts up to four 50 Watt or 100 Watt units and three 150 Watt units;...
  • Page 2 UL method, 120V a-c: 0.5 mA maximum. VDE method, 240V a-c: 0.75 mA maximum. KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 228-1301 REV 4...
  • Page 3 # INPUT POWER: Line (either a-c or d-c source power), Neutral and Ground (chassis) FIGURE 2. REAR CONNECTOR PIN ASSIGNMENTS FIGURE 3. TYPICAL ALARM CIRCUIT DIAGRAMS KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 082306...
  • Page 4 DIMENSIONS: See Figure 5. AMBIENT TEMPERATURE WARRANTY: 5 years. FIGURE 5. HSF POWER SUPPLY OUTLINE DRAWING KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 228-1301 REV 4 082306...

This manual is also suitable for: