Scan
Global min./max. code length: Global Minimum and
Maximum length can be set to qualify data entry. The length
is defined as the actual barcode data length to be sent. Label
with length exceeds these limits will be rejected. Make sure
that the Minimum length setting is no greater than the
Maximum length setting, or otherwise the labels of the
symbology will not be readable. In particular, you can set the
same value for both Minimum and Maximum reading length
to force the fixed length barcode decoded. The values of
setting have no effect on
length.
Notes 1): Please set the min/max length if you have special
demand for individual barcode.
2): Include the Check sum digits if you want to set
Global min/max code length.
Inverted image scan: Set Enabled the scanner will scan
both black/white barcode with white/black background.
CTS trigger: This operation enabled an external device to
control scanning. The CTS trigger is controlled by apply an
external trigger signal to the CTS input. When active, this
signal causes scanning to begin as the scanner's trigger was
depressed.
Position indication: This function can indicate the specific
location before scanning. You can also set up the time of
indication.
certain symbologies with