Download Print this page

KEPCO HSF 5-10-1U Instruction Manual

Single output, 1u, 50 watt hot swap plug-in power supplies

Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
KEPCO
KEPCO SINGLE OUTPUT, 1U, 50 WATT
HOT SWAP PLUG-IN POWER SUPPLIES
I — INTRODUCTION
The Kepco HSF-1U 50 Watt Series hot swappable, high frequency switching, plug-in power supplies employ forward conversion
and are designed to operate in a fault tolerant power system with either a-c or d-c input. A thermistor soft-start circuit limits
start-up surge. A built-in forced current share circuit and OR-ing diodes allow configuration for hot-swap and parallel-redundant
N+1 operation.
These power supplies are designed to be used with Kepco's Series RA 19-1U rack adapters. The RA 19-1U rack adapter
accepts up to four 50 Watt or 100 Watt units (see Figure 1). All input/output connections are through a 24-pin connector that
plugs in to the rack adapter. All external connections are made through the rack adapter. Surface mount technology permits effi-
cient component layout for minimum mounting space.
Five models may be selected for outputs of 5, 12, 15, 24, or 48V (see Table 1).
When the input is cut off, the output is maintained for 15 milliseconds minimum. If the power supply shuts down due to an output
overvoltage condition, it is then necessary to wait 60 seconds minimum before turning the unit on again. EMI filtering is
designed to meet FCC Class B rating and VDE 0871 Class B rating. This page contains specifications for each model of the
HSF-1U 50 Watt Series. Environmental specifications for each model are the same.
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1U 50W SERIES
MODEL
OUTPUT VOLTS, d-c (NOMINAL)
ADJUSTMENT RANGE
OUTPUT CURRENT (NOMINAL)
OUTPUT POWER (NOMINAL)
source (typ)
RIPPLE
source (max)
AND
NOISE
switching (typ)
(mV p-p)
0-40°C
switching (max)
10-100% LOAD
spike noise (d-c—50MHz)
OVERVOLTAGE SETTING 25 °C, NOM. INPUT
OVERCURRENT SETTING 25 °C, NOM. INPUT
Rectangular type characteristic
(1) Derates same as Ouptut Power.
(2) See power derating curve, Figure 4.
II — FEATURES
FRONT PANEL ACCESS. The front panel provides a power ON/OFF switch controlling input power and a "VDC ON" light
which indicates when the unit is operating. NOTE: The ON/OFF switch must be set to OFF before removing unit from rack
adapter. The front panel "MASTER ON" LED lights when 1) the unit operates independently, or 2) the unit is used in parallel
redundant configurations while a) the output is less than 10% of nominal or b) the output is within 10% to 100% of nominal and
the unit is functioning as a master. In parallel redundant configurations, the module with the highest voltage functions as the
master. The other units are slaves, and track the output voltage of the master. Refer to Current Share Bus (CSB) on page 3 for
details. The front panel Vadj trimmer provides adjustment of the output voltage within the limits specified in Table 1; test points
connected to the +S and –S lines are available at the front panel for measuring the output.
FORCED CURRENT SHARE CIRCUIT. When units are configured for N+1 parallel redundant operation, it is desirable for cur-
rent to be divided equally among the paralleled supplies. When the CSB (Current Share Bus) lines of paralleled HSF-1U units are
connected together, the load current is forced to divide equally between all paralleled units. If one unit fails, the remaining units
will continue to supply the load, and the load current will be divided equally among the remaining operating units. The failed unit
is automatically isolated from the circuit by a built-in isolation diode. Refer to Current Share Bus (CSB) on page 3 for details.
KEPCO, INC.
"
131-38 SANFORD AVENUE
©2006, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
HSF 5-10-1U
5.0V
4.5 - 5.5V
(1)
10.0A
(2)
50.0W
10
20
30
60
120
6.5 - 7.5V
10.5 - 12.0A
" FLUSHING, NY. 11352 U.S.A.
http://www.kepcopower.com "
HSF 12-4.2-1U
HSF 15-3.4-1U
12.0V
15.0V
11.4 - 12.6V
13.5 - 16.5V
4.2A
3.4A
50.4W
51.0W
15
15
30
30
35
45
70
90
190
220
13.7 - 15.7V
17.0 - 19.0V
4.4 - 5.1A
3.6 - 4.1A
" TEL (718) 461-7000
email: hq@kepcopower.com
228-1453 REV 3
HSF-1U
50W
HSF 24-2.1-1U
HSF 48-1-1U
24.0V
48.0
22.5 - 25.5V
45 - 51V
2.1A
1.0A
50.4W
48W
25
30
30
60
50
60
100
150
310
350
27.0 - 30.5V
53.5 - 60.0
2.2 - 2.6A
1.1 - 1.3A
"
FAX (718) 767-1102
1

Advertisement

loading

Summary of Contents for KEPCO HSF 5-10-1U

  • Page 1 N+1 operation. These power supplies are designed to be used with Kepco’s Series RA 19-1U rack adapters. The RA 19-1U rack adapter accepts up to four 50 Watt or 100 Watt units (see Figure 1). All input/output connections are through a 24-pin connector that plugs in to the rack adapter.
  • Page 2 III — SPECIFICATIONS The following specifications apply to HSF-1U 50 Watt Series models (also refer to Table 1). Other models are also available; consult your Kepco representative for their specifications. INPUT: Voltage: 120V a-c/240V a-c nominal; Range 95-264V a-c; 125-370V d-c. (polarity insensitive; consult factory) Frequency: Nominal 50-60 Hz;...
  • Page 3 (If forced current sharing at less than 10% nominal current per supply is needed, contact Kepco application engineering.) Remote sensing is recommended. For master/slave operation to work properly each unit should be adjusted to 40 mV (optimum) less than the next paralleled unit (unit 1 is adjusted to VOUT, unit 2 to VOUT –...
  • Page 4 B) PCB 0.063" THK FR-4 1.108 [28.2] C) FRONT PANEL 0.090 THK. ALUM. 6061-T6 0.471 [12.0] 2. FINISH: FRONT PANEL -KEPCO DUAL TONE GRAY 1.732 [44.0] 0.125 [3.2] 3. MODULE IS KEYED AS SHOWN IN DETAIL 4. DIMENSIONS ARE IN INCHES, [DIMENSIONS IN BRACKETS 0.780 [19.8]...

This manual is also suitable for:

Hsf 15-3.4-1uHsf 12-4.2-1uHsf 24-2.1-1uHsf 48-1-1uHsf 5-10Hsf 12-4.2 ... Show all