Ericsson MASTR IIe Maintenance Manual page 7

Utility handset
Table of Contents

Advertisement

CG Encode Disable
Start: Disable channel guard encode.
Stop: Restore the original EEPROM setting.
CG Decode Disable
Start: Disable channel guard decode.
Stop: Restore the original EEPROM setting.
RUS MUTE
Start: Disable the main receiver.
Stop: Restore the original EEPROM setting.
CG Monitor
Start: Enable the Channel Guard monitor function.
Stop: Restore the original EEPROM setting.
Remote PTT
Start: Key remote push-to-talk.
Stop: Unkey remote push-to-talk.
Local PTT
Start: Key local push-to-talk.
Stop: Unkey local push-to-talk.
External PTT
Start: Key external push-to-talk.
Stop: Unkey external push-to-talk.
Morse Code
Start: Send Morse code ID if one is programmed.
Stop: Disable Morse code ID function.
Comments: If no ID is present, START will have no effect. If
STOP is selected while station is transmitting ID, ID will be
interrupted and terminated.
Battery Alarm Disable
Start: Disable battery Alarm Tone.
Stop: Restore the original EEPROM setting.
Test Tone
Start: Begin sending test tone.
Stop: Stop sending test tone.
Comment: The test tone frequency is 1000 Hertz.
Soft Boot
Start: Toggles software reset.
Stop: No function.
Carrier Control Timer Disable
Start: Disable the carrier control timer.
Stop: Restore the original EEPROM setting.
RUS Disable
Start: Enable Receiver Unsquelched Push to Talk.
Stop: Restore the original EEPROM setting.
Scan Enable
Start: Enable SCAN.
Stop: Restore original EEPROM setting.
Scan Disable
Start: Disable SCAN.
Stop: Restore original EEPROM setting.
Main Rx Enable
Start: Enable the main receiver.
Stop: Restore the original EEPROM setting.
Main Rx Disable
Start: Disable the main receiver.
Stop: Restore the original EEPROM setting.
Aux Rx Enable
Start: Enable the auxiliary receiver and toggle Aux Rx Mute.
Stop: No function.
Aux Rx Disable
Start: Disable the auxiliary receiver and toggle Aux Rx Mute.
Stop: No function.
Aux Control 1 On
Start: Activate Auxiliary 1 output.
Stop: Restore the original EEPROM setting.
Aux Control 1 Off
Start: Deactivate Auxiliary 1 output.
Stop: Restore the original EEPROM setting.
Priority Scan Disable
Start: Disable Priority SCAN.
Stop: Restore EEPROM setting of Priority SCAN Enable.