3.2 Checking Magnetron Heater Voltage

Magnetron heater voltage is formed on the MD (1824C), PTU (1834C) or RTB
(1934C/1944C1954C) Board of the antenna unit, and preadjusted at the factory. Therefore,
no adjustment is required. However, check magnetron heater voltage for confirmation as
shown below. This procedure should only be performed by a qualified technician.
1. Open the antenna unit.
2. Turn on the power. Do not transmit the radar.
3. Connect a multimeter, set to 10VDC range, appropriate position on the MD (1824C),
PTU (1834C) or RTB (1934C/1944C1954C) Board in the antenna unit. Refer to the table
in below.
4. Confirm that the multimeter indication is within the ratings shown below.
TP804#6 (+) and #4
Check point
(-) on MD Board
Multimeter
7.9 to 8.1 V
indication
Adjustment point

3.3 Remote Controller Setting

A remote controller can be set exclusively for use with a specific display unit, in the case of
multiple NavNet display units. Set the remote controller ID mode desired on the menu and
attach appropriate label (supplied with accessories) to the remote controller and display
unit.
1. Press the MENU key followed by the SYSTEM CONFIGURATION and GENERAL
SETUP soft key to show the GENERAL SETUP menu.
KEY BEEP
LANGUAGE
RANGE UNIT
TEMPERATURE UNIT
DEPTH UNIT
WIND UNIT
WIND DATA
SPEED AVERAGING
LOCAL TIME OFFSET
RESET TRIP LOG
TIMEOUT DISPLAY SETTING 15 sec
SAVE MOB KEY FUNCTION SAVE SHIP
WALLPAPER
Page 1
2. Press the NEXT PAGE soft key to show Page 2.
MODEL1824C
TP802#4 (+) and #6 (-)
on PTU Board
7.4 to 7.6 V
VR801 on MD Board
ON
ENGLISH
nm, kt
°F
ft
ft
APPARENT
60 seconds
9H 0m
NO
POSITION & MOB
DEFAULT
GENERAL SETUP menu
3-13
MODEL1834C
R106 on PTU Board
LAT/LON DISPLAY
TD DISPLAY
SPEED
POSITION DISPLAY
TIME DISPLAY
INFRARED REMOTE MODE A
RANGE & BEARING MODE
BEARING READOUT
MAGNETIC VARIATION
Page 2
MODEL1934C/1944C/
1954C
J825#4 and #6 (GND) on
RTB Board
7.4 to 7.6 V
VR801 on MD Board
DD˚MM.MMMM'
LORAN C
SOG
LAT/LON
24 HOURS
RHUMB LINE
MAGNETIC
AUTO 07.0°E

Hide quick links: