Installation - Simer 3105P Owner's Manual

Hide thumbs Also See for 3105P:
Table of Contents

Advertisement

Available languages

Available languages

Installation

To Household
Water System
Pump Priming
Tee with Plug
or Gauge
Priming
Tee and
Plug
Drive point
below water
level
Not
to
Scale
Figure 1: Driven Point Installation
To Household
Water System
Pump Priming
Tee with Plug
or Gauge
Check
Valve
Not
to
10'
Min.
Scale
5–10'
1862 0205 SWJ
Figure 2: Cased Well Installation
For parts or assistance, call Simer Customer Service at
Replacing An Old Pump
ing on pump or motor.
Step 1. Drain and remove the old pump. Check the old pipe for scale, lime,
rust, etc., and replace it if necessary.
Step 2. Install the pump in the system. Make sure that all pipe joints in the
suction pipe are air-tight as well as water tight. If the suction pipe
can suck air, the pump will not be able to pull water from the well.
Step 3. Adjust the pump mounting height so that the plumbing connections
do not put a strain on the pump body. Support the pipe so that the
pump body does not take the weight of piping or fittings.
You have just completed the well plumbing for your new shallow
Check
well jet pump. Please go to Page 6 for discharge pipe and tank
Valve
connections.
WELL POINT (DRIVEN POINT) INSTALLATION
(Figure 1)
Drive
Step 1. Drive the well, using "drive couplings" and a "drive cap". "Drive
Coupling
fittings" are threaded all the way through and allow the pipe ends to
Drive
butt against each other so that the driving force of the maul is car-
Point
ried by the pipe and not by the threads. The ordinary fittings found
in hardware stores are not threaded all the way through the fitting
and can collapse under impact. "Drive fittings" are also smoother
than standard plumbing fittings, making ground penetration easier.
Step 2. Mount the pump as close to the well as possible.
Step 3. Use the fewest possible fittings (especially elbows) when connecting
the pipe from the well point to the pump suction port. The suction
pipe should be at least as large as the suction port on the pump
(include a check valve if your pump is not equipped with one – see
Figure 1). Support the pipe so that there are no dips or sags in the
pipe, so it doesn't strain the pump body, and so that it slopes slight-
ly upward from the well to the pump (high spots can cause air
pockets which can air lock the pump). Seal the suction pipe joints
Suction Pipe
with teflon tape or a teflon based pipe joint compound. Joints must
From Well
be air- and water-tight. If the suction pipe can suck air, the pump
cannot pull water from the well. If one well point does not supply
enough water, consider connecting two or three well points to one
suction pipe.
Priming
Tee and
You have just completed the suction piping for your new shallow
Plug
well jet pump. Please go to Page 6 for discharge pipe and tank
connections.
Sanitary
Well Seal
CASED WELL INSTALLATION, 2" OR LARGER
CASING (Figure 2)
Step 1. Mount the pump as close to the well as possible.
Step 2. Assemble the foot valve, strainer, and well pipe (see Figure 2). Make
Foot
sure that the foot valve works freely.
Valve
Step 3. Lower the pipe into the well until the strainer is five feet above the
bottom of the well. It should also be at least 10 feet below the well's
water level while the pump is running in order to prevent the pump
from sucking air. Install a sanitary well seal.