Simer 3105P Owner's Manual page 5

Hide thumbs Also See for 3105P:
Table of Contents

Advertisement

Available languages

Available languages

Installation
To Household
Water System
Pump Priming
Tee with Plug
or Gauge
Not
to
Scale
10'
Foot
Min.
Valve
Screen
5–10'
Figure 3: Surface Water Installation
For parts or assistance, call Simer Customer Service at
Step 4. Install a priming tee, priming plug, and suction pipe to the pump
(see Figure 2). Connect the pipe from the well to the pump suction
port, using the fewest possible fittings – especially elbows – as fit-
tings increase friction in the pipe (however, include a foot valve –
see Figure 2). The suction pipe should be at least as large as the
Suction Pipe
suction port on the pump. Use teflon tape or a teflon-based pipe
From Well
joint compound on threaded pipe joints. Support the pipe so that
there are no dips or sags in the pipe, so it doesn't strain the pump
body, and so that it slopes slightly upward from the well to the
pump (high spots can cause air pockets which can air lock the
pump). Seal the suction pipe joints with teflon tape or a teflon
based pipe joint compound. Joints must be air- and water-tight.
If the suction pipe can suck air, the pump cannot pull water from
the well.
You have just completed the suction piping for your new shallow
well jet pump. Please go to Page 6 for discharge pipe and tank
connections.
INSTALLATION FOR SURFACE WATER (Figure 3)
could be used for sprinkler applications.
Step 1. The pump should be installed as close to the water as possible,
with the fewest possible fittings (especially elbows) in the suction
pipe. The suction pipe should be at least as large as the suction port
on the pump.
Step 2. Assemble a foot valve and suction pipe (see Figure 3). Make sure
that the foot valve works freely. Use teflon tape or a teflon-based
pipe joint compound on threaded pipe joints. Protect the foot valve
assembly from fish, trash, etc, by installing a screen around it (see
Figure 3).
Step 3. Lower the pipe into the water until the strainer is five feet above the
bottom. It should also be at least 10 feet below the water level in
order to prevent the pump from sucking air.
Step 4. Install a priming tee, priming plug, and suction pipe to the pump
(see Figure 3). Support the pipe so that there are no dips or sags in
the pipe, so it doesn't strain the pump body, and so that it slopes
slightly upward from the well to the pump (high spots can cause air
pockets which can air lock the pump). Seal the suction pipe joints
with teflon tape or a teflon based pipe joint compound. Joints must
be air- and water-tight. If the suction pipe can suck air, the pump
cannot pull water from the well.
You have just completed the plumbing for your new shallow well jet
pump. Please go to Page 6 for discharge pipe and tank connections.
Do not use surface water for drinking. The installation shown
1-800-468-7867 / 1-800-546-7867