HYDRAULIC OPERATOR PH 275 - PH 390
These instructions apply to the following models: PH 275 R, PH 275 BA, PH 275 BC, PH 275 BAC, PH 390 R,
PH 390 BA, PH 390 BC, PH 390 BC, PH 390 BAC.
The hydraulic operator PH 275 and PH 390 for swing gate, they are constituted by an enbloc composed of an electric pump and
a hidraulic piston that transmits the movement to the the gate.
The models endowed with hydraulic lock (BA - BC - BAC) don't require the installation of electric lock, as they guarantee
mechanical locking of the leaf when the motor is not operating.
The models without a hydraulic locking, (R) require the installation of electric locks to ensure the leaf is mechanically locked.
The hydraulic operator PH 275 and PH 390 whose designed and produced for to automate swing gates.
To avoid any other use.

1. DESCRIPTION AND TECHNICAL SPECIFICATIONS

1.1. DIMENSIONS PH 275 - PH 390
LENGTH (A)
PH 275
PH 390
1.2. OPERATOR DESCRIPTION PH 275 - PH 390
1) Electric motor
2) Release lock
3) Hydraulic piston
4) Cylinder
5) By-pass valves
6) Pump
7) Electrical power cable

DIMENSIONS (mm)

Distance attacks (B)
Rod stroke (C)
8) Front attack
9) Cover for stroke
10) Kit release
11) Rear attack
12) Rod end
2. ELECTRIC STANDARD DEVICES
1) Hydraulic operators
2) Photocells
3) Electronic control box
4) Key selector
You needs always to separate the connecting cables
of the low voltage accessories from the 230 V.
Use separate sheaths to avoid any type of interference.
Connect power cables hydraulic operator:
- Co (Common) = gray cable
- Ap (open) = brown cable
- Ch (closing) = black cable
- T (earth) = yellow / green
3. INSTALLING SYSTEM
3.1. PRELIMINARY CHECKS OF THE GATE
For a correct operating gate must satisfy the following
conditions:
- robust and rigid structure of the leaves;
- the leaf movement should be smooth and uniform but without
any friction during the race;
- the hinges must be in excellent state;
- limit mechanical stops placed.
Any metalwork shall be conducted before installation of
automation.
The state of the gate structure influence the reliability and
safety of the automatism.
5) Receiver
6) Flashing light
7) Electric lock