FAQ
I/O Terminal Connector - Pin Assignment
Pin
Function
COMMON
1
RELAY_NO
2
DGND
3
DIGI input
4
DGND
5
Load default
6
Restore Factory Default
To restore factory default, please follow the steps:
1.
Unplug the power jack to turn off the camera
2.
Short pin 5 and pin 6 with a wire
3.
Plug in the power jack to turn on the camera. The power LED will start flashing in a short while.
4.
Break the short when the LED starts quick flashing. Wait for a few minutes the device should be
set back to factory default.