Chamberlain MH 5011U User Manual page 3

Medium duty logic
Hide thumbs Also See for MH 5011U:
Table of Contents

Advertisement

BASIC PROGRAMMING
DETERMINE THE WIRING TYPE
ALTERNATE INSTALLATION: C2 WIRING TYPE WITH MONITORED
ENTRAPMENT PROTECTION DEVICE
• Momentary contact to open and stop with constant pressure to
close.
• Open override that reverses when closing by any opening
device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring
when Monitored Entrapment Protection Device is installed. (See
accessories page for Monitored Entrapment ProtectionDevices.)
• Timer-to-Close (TTC) feature not available.
MONITORED ENTRAPMENT PROTECTION DEVICE
Photoelectric Sensor
To Program:
Press and hold the LEARN and CLOSE buttons until the LED
1
goes out (approximately 3 seconds).
Electrical Box
Logic Board
D7
D5
U4
D6
D4
J4
014A1030
C32
C20
TP1
R25
C9
U1
C21
L5
^^^^
AUX ANT
AUX ANT
C18
J2
R27
D14
K2
LT
TTC
LEARN
STOP CLOSE OPEN
LED
C29
1
2
3
4
5
6
7
R24
P1
D9
LMEP1
LMEP2
COM
INTRLK
STOP
CLOSE
OPEN
To Reset to B2 with Monitored Entrapment Protection Device:
Press and hold the LEARN and STOP buttons until the LED
1
goes out (approximately 3 seconds).
LEARN
STOP CLOSE OPEN
D14
LED
1
2
3
4
5
6
ALTERNATE INSTALLATION: C2 WIRING TYPE WITHOUT
MONITORED ENTRAPMENT PROTECTION DEVICE
(FACTORY DEFAULT)
• Momentary contact to open and stop with constant pressure to
close.
• Open override that reverses when closing by any opening
device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring
when Monitored Entrapment Protection Device is installed.
(See accessories page for Monitored Entrapment Protection
Devices.)
• Timer-to-Close (TTC) feature not available.
NON-MONITORED ENTRAPMENT PROTECTION DEVICE
Sensing Edge
Reset to FACTORY DEFAULT (C2) without Monitored Entrapment
Protection Device:
1
Remove any monitored entrapment protection devices.
2
Press and hold the LEARN and STOP buttons until LED goes
out (approximately 3 seconds).
7
3

Hide quick links: