Download Print this page
Chamberlain MGJ User Manual
Chamberlain MGJ User Manual

Chamberlain MGJ User Manual

Medium duty logic
Hide thumbs Also See for MGJ:

Advertisement

Quick Links

MH 5011E
MHS 5011E
MGJ 5011E
Contact Information
Installation Date
www.liftmaster.com
MEDIUM DUTY LOGIC
USER'S GUIDE
MJ 5011E
MT 5011E
BMT 5011E
Radio Receiver
Built on Board
315MHz

Advertisement

loading

Summary of Contents for Chamberlain MGJ

  • Page 1 MEDIUM DUTY LOGIC USER’S GUIDE MH 5011E MHS 5011E MT 5011E BMT 5011E MGJ 5011E MJ 5011E Contact Information Radio Receiver Built on Board Installation Date www.liftmaster.com 315MHz...
  • Page 2: Determine The Wiring Type

    315 MHz product line as well as a Timer To Close (TTC) Commercial Door Operator. Your new operator is capable of feature that can be enabled when LiftMaster Commercial Protector ® operating up to 12 cycles per hour or 50 cycles per day. It is System is installed and aligned properly.
  • Page 3 B A S I C P R O G R A M M I N G B2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE B2 WIRING TYPE WITH MONITORED SAFETY DEVICE Requires a non-monitored safety device. • Momentary contact to open, close and stop. •...
  • Page 4 5 to 60 seconds. ® Built in 315 MHz radio receiver permits as many as 20 Security✚ Requires LiftMaster monitored safety device. remote controls or dip switch remote controls in any combination. TO PROGRAM TO PROGRAM 1.
  • Page 5 M A N U A L D I S C O N N E C T ( M O D E L S M T / B M T & M H ) WARNING The operators have provisions for manually operating the door in CAUTION CAUTION case of emergency or power failure.
  • Page 6 When operator is disconnected by the manual operation chain, hoist and electrical operation will not function. ATTENTION Chain Retaining Bracket (with pad locking provisions) Hoist Chain Manual Disconnect for Models MJ and MGJ Electrical Interlock with Hoist Chain (when present) for Model MHS ADVERTENCIA PRECAUCIÓN...
  • Page 7 3. Press CLOSE button. (The door should move in the close TEST REMOTE CONTROL direction.) * Requires B2 wiring type and compatible LiftMaster remote 4. Release CLOSE button. Door should stop if in C2 mode. (The control. In C2 wiring the remote control will open the door should continue closing if in B2 mode.)
  • Page 8: Troubleshooting

    T R O U B L E S H O O T I N G To locate a dealer in your area visit us online at www.liftmaster.com CONDITION POSSIBLE CAUSE ➤ Check circuit breaker. OPERATOR WILL NOT No power RESPOND TO ANY COMMANDS ➤...
  • Page 9 O P E R A T O R N O T E S...
  • Page 10 O P E R A T O R N O T E S...
  • Page 11 O P E R A T O R N O T E S...
  • Page 12 A C C E S S O R I E S ENTRAPMENT PROTECTION DEVICES REMOTE CONTROLS 315MHz Monitored ® 371LM 1-Button SECURITY✚ Remote Control: PRESS Commercial Protector R ING CPS-LN4 Includes visor clip. ® System Provides protection on doors up to 45' wide.