Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Phillips screwdriver
Flat-blade screwdriver
Measuring tape
Level
Drill
1
/
" (3.5 cm) hole saw
3
8
Parts supplied
Two #8-18 x
/
" screws
1
2
Lens (for panel ready models)
Check local codes. Check existing electrical supply. See
"Electrical Requirements."
It is recommended that all electrical connections be made by
a licensed, qualified electrical installer.
Product Dimensions
WARMING
DRAWER
SIZE
24" (60.9 cm)
27" (68.6 cm)
30" (76.2 cm)

INSTALLATION REQUIREMENTS

A
E
OVEN
RECESSED
DEPTH (A)
WIDTH (B)
23
/
" (58.7 cm)
22
/
" (56.5 cm)
1
1
8
4
23
/
" (58.7 cm)
25
/
" (64.1 cm)
1
1
8
4
23
/
" (58.7 cm)
28
/
" (71.8 cm)
1
1
8
4

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Cutout dimensions that are shown must be used. Given
dimensions provide minimum clearance with warming
drawer.
Recessed installation area must provide complete enclosure
around the recessed portion of the warming drawer.
Grounded electrical supply is required. See "Electrical
Requirements" section.
Electrical supply outlet should be located in the rear wall
on the upper right-hand side of the cutout or in an adjacent
cabinet. The outlet must be recessed. If the electrical outlet
is located in an adjacent cabinet, a 1
diameter hole should have been drilled in the back of the
cutout or support surface to pass the power supply cord
through to the outlet.
Warming drawer support surface must be solid, level,and
flush with bottom of cabinet cutout.
Warming drawers with oiled bronze, black glass, and white
glass panels are approved for indoor use only.
Support surface must be solid, level, and flush with the
bottom of the cabinet cutout.
24" (61.0 cm) minimum cabinet depth.
For best performance results make sure the warming drawer is
leveled before completing installation. There is no way to level
the warming drawer after it has been installed. If the installation
is not level, the door may slide open or not seal tightly, allowing
heat to escape.
NOTE: If installing the warming drawer below another product,
refer to that product's literature for any installation requirements.
B
D
RECESSED
OVERALL
HEIGHT (C)
WIDTH (D)
9" (22.9 cm)
23
/
" (60.3 cm)
3
4
9" (22.9 cm)
26
/
" (67.9 cm)
3
4
9" (22.9 cm)
29
/
" (75.6 cm)
3
4
/
" (3.5 cm) minimum
3
8
C
DRAWER
FRONT
HEIGHT (E)
10
/
" (26.1 cm)
1
4
10
/
" (26.1 cm)
1
4
10
/
" (26.1 cm)
1
4
3

Hide quick links: