4-5. Leveling the appliance

Once the appliance is positioned, adjust the feet (screwing them in or out) to adjust the
dishwasher, making it level. In any case, the appliance should not be inclined more than 2°. If the
appliance is level, it will help ensure proper performance.

4-6. Cold water connection

Connect the water supply hose to a threaded 3/4 (gas) connector, making
sure that it is fastened tightly in place (see fig.A).
Some models are fitted with an "Aquastop" water supply hose (see fig.B)
fig.A
in which the small filter is already housed in the threaded end.
If the water pipes are new or have not been used for an extended period
of time, let the water run to make sure that the water is clear and free of
impurities. If this precaution is not taken, there is a risk that the water inlet
can get blocked and damage the appliance.
fig.B
Warning
The appliance is to be connected to the water mains using new hose-sets and that old
hose-sets should not be reused.

4-7. Drain hose connection

Insert the drain hose into a drain pipe with a minimum diameter of 4cm, or let it run into the sink,
making sure to avoid bending or crimping it. If necessary, fit a syphon trap (U-bend) with a
connecting piece for the drain hose (fig.C). The free end of the hose must be at a height between
40 and 100 cm and must not be immersed in water.
fig.C
Attention:
The connecting piece for syphon trap (U-bend) must be securely fastened to the wall to
prevent the drain hose from moving and allowing water to spill outside the drain.