Honeywell 6162 Programming Manual page 3

Advertisement

Menu 3: Enabling System Reports (for ADEMCO Contact ID
NOTES:
This menu lets you enable various system reports if
®
ADEMCO Contact ID
selecting yes or no for each report. If another report
format is desired, use standard control panel
programming mode (installer code + 800) to program
these reports. Refer to the field number column for the
respective programming field in standard programming
mode.
System Reports
Programming Option
a. RF Jam Report
b. Cancel Report
c. Event Log Full Report
d. Exit Error Report
e. Open Report
f. Close Away Report
(Arm Away)
g. Close Stay Report
(Arm Stay)
Menu 4: Timing and Miscellaneous Options
NOTES:
This menu lets you set entry/exit delays, alarm
sounding timeouts, installer code, and enable the auto-
stay option. To program other options, use standard
control panel programming mode (installer code + 800).
Refer to the field number column for the respective
programming field in standard programming mode.
Timing and Miscellaneous Options
Scroll Backward: Use the C key; Scroll Forward: Use the D key.
Dashed boxes: Indicates the entry is available only for partitioned systems (ex. VISTA-20P, VISTA-21iP).
Programming Option
a. Exit Delay
b. Entry Delay 1
c. Entry Delay 2
d. Alarm Sounder (Bell)
Timeout
e. Fire Alarm Sound
Timeout
[Fire Snd. Timeout]
f. Installer Code
g. Auto-Stay
format is being used by
Event
Part 1
Part 2
Part 3
Part 1
Part 2
Part 3
Part 1
Part 2
Part 3
Entries
|
|
Part. 1
Part. 2
|
|
Part. 1
Part. 2
|
|
Part. 1
Part. 2
|
|
|
®
reporting only)
System Reports
RF Jam
N
Log Full
Exit Error
Open Report
Close Away
Close Stay
Field
∗22
To enable/disable a report:
0 = No
∗68
1 = Yes
∗89
To toggle the entry, use the D key.
Dashed boxes: Indicates the entry is available
∗59
only for partitioned systems (ex. VISTA-20P,
VISTA-21iP).
∗65
∗66
∗66
Timing / Misc
Exit Delay
Entry 1 Delay
Entry 2 Delay
A l a r m S o u n d T i m e :
Fire Snd. Timeout
Installer Code
Auto Stay:
Field
00 - 96 = 0 - 96 seconds
∗34
97 = 120seconds
SIA Controls: Entries less than 45 result in 45-sec. delay.
00 - 96 = 0 - 96 seconds
∗35
97 = 120seconds
SIA Controls: Entries less than 30 result in 30-sec. delay.
See Entry Delay 1 for entries.
∗36
0 = none
3 = 12 min
∗33
1 = 4 min
4 = 16 min
2 = 8 min
0 = Yes - sound stops at timeout set in field ∗33
∗32
1 = No - no timeout
4 digits, 0000-9999
∗20
0 = no
∗84
1 = part. 1 only
– 3 –
Cancel
N
N
N
P1
P2
P3
N
N
N
N
N
N
N
N
N
Notes
P1
P2
60
60
30
30
30
30
4M
N
xxxx
Part 1 & 2
Notes
98 = 180seconds
99 = 240seconds
2 = part. 2 only
3 = part. 1 & part 2

Advertisement

loading

This manual is also suitable for:

6162v6162rf