Programming Mode - Honeywell 6162 Programming Manual

Advertisement

e. Serial Number
f. Response Time
g. Configuration
(Hardwire Type)
h. Library
(Zone Descriptor)
Menu 7: Quit Menu Mode Programming
NOTES:
Use this menu to exit Menu mode programming. After
exiting, the "Communicating" message appears
briefly, indicating the control is being updated with the
programmed information.
Quit Menu
Programming Option
a. Exit – Allow Re-Entry
b. Exit – Block Re-Entry
c. Back to 1st Page
|
|
|
|
|
|
Serial Number
Loop
word 1
word 2
word 3
Entries
1
2
3
– 5 –
Manually enter the 7-digit serial number printed on
the label of the transmitter.
Press the [∗] key to move to the "Loop" position,
and then enter the loop number.
To delete an existing serial number, enter 0 in the
∗56
loop number field. The serial number will change to
0's. If 0 was entered in error, simply re-enter the
loop number or press [#], the serial number will
return to the display.
Press [∗] to advance.
Applies only to hardwire zones 1-8.
0 = 10mSec
1 = 350mSec
∗56
2 = 700mSec
3 = 1.2 seconds
Press [∗] to advance.
Applies only to hardwire zones 1-8.
0 = EOL
1 = NC
∗56
2 = NO
3 = zone doubling (ZD) (V20P/V21iP only)
4 = double-balanced (DB) (V20P/V21iP only)
Press [∗] to advance.
For each descriptor word for this zone, enter the
3-digit number from the Vocabulary list.
(see Library list of descriptors on the back page or
∗82
in the controls' Programming Guide)
Press [∗] to return to the Zone Number prompt to
program the next zone or advance to the Quit menu.
QUIT QUICK

PROGRAMMING MODE

1 – Exit – Allow Re-entry
2 – Exit – Block Re-entry
3 – Back to 1st Page
Field
Exits program mode and allows re-entry by:
∗99
Installer Code + 8 0 0, or pressing [∗] and [#] at the
same time within 50 seconds of powering up
Exits programming mode and prevents re-entry by:
Installer Code + 8 0 0.
To reenter programming mode, the system must be
powered down, then powered up. Then press [∗]
∗98
and [#] at the same time within 50 seconds of
powering up.
For other ∗98 program mode lockout options, see
field ∗88 in standard control panel programming
mode (installer code + 800).
Press 3 to return to the first page of Menu mode
--
programming.
Notes