Boiler and combustion product drain outlet mainte-
nance must be carried out annually by qualified
staff.
Spare parts must be ordered using the references
given in chapter IX - NOMENCLATURE, specifying

1 - CLEANING THE BOILER SHELL

For FCX 30 C models only:
!
- remove the burner before removing
the baffling (item no. E).
- Unclip the top of the boiler casing by pulling it
upwards,
- unscrew the 4 fixing screws (item no. B) from the
cast-iron plate (item no. E)
- remove the flue outlet (item no. D),
- remove the baffles (rep. E),
FCX 22 C
Fig. 62
B
VI - MAINTENANCE
B
C
B
C
D
B
P
E
13
13
the type and serial number of the device.
Before any operation, cut off the power
!
supply. Close the system oil inlet and
the water stopcocks if necessary.
- clean the walls of the boiler shell (item no. 13),
- reassemble all the parts and be sure
• not to reverse them,
• to position the combustion chamber pipe
(item no. D) with its centering screw (item no.
P) towards the front of the boiler,
• to position the cast-iron plate arrow marker
(item no. C) opposite the centering screw (item
no. P).
B
- 40 -
FCX 30 C
C
B
C
D
B
P
E
13
13
B