Commissioning Procedure - With Regulator; Commissioning The Oil Burner - geminox FCX 22 C Technical Instructions

Hide thumbs Also See for FCX 22 C:
Table of Contents

Advertisement

- For commissioning with the summer setting:
• For the FCX models:
. Stop the boiler using the Stop/Start switch
(item no. 1),
• For the FCX + domestic hot water production
tank models or other type:
. press the Summer/Winter switch (item
no. 2) - Summer position,
. set the tank domestic hot water thermostat
to the required temperature,
. position the boiler temperature thermostat
(item no. 3) to the minimum,
. set the mixer valve (fig. 2, item no. 5) to po-
sition "0".
Fig. 59
3
-
In the summer it is advisable to operate
!
the heating pump for several minutes to
avoid any risks of fouling (see §
section 4 - page 41).
(When the boiler is equipped with an
electronic regulator, this function is
performed automatically).
6.2 - Commissioning
regulator
See the regulator technical instructions for tempera-
ture control.
Set the boiler temperature thermostat
!
(item no. 3) to maximum.
1
procedure
-
with

6.3 - Commissioning the oil burner

- When commissioning the oil burner for the first ti-
me:
• check that the smoke spot number does not
exceed 0.5 (BACHARACH control),
• check the CO2 rate - 11.5 to 12.5 %, CO < 100
ppm (watch out for secondary air inlets),
• check the temperature of the combustion pro-
ducts (under 120 °C).
Models
GEMINOX
oil burner
Heat flow
kW
Pump
bar
pressure
Spray nozzle
Oil inlet setting
Air setting
(FCX balanced flue
outlet)
Remark:
- The burners are preset in the factory for the ba-
lanced flue model FCX. Nevertheless the air and
oil inlet settings must be checked systematically
on commissioning and after all maintenance ope-
rations on the burner by testing the opaqueness
of the flue gasses and of the % CO2 - See the
burner technical instructions.
- For the installed flue model FCX boilers the air
setting must be readjusted to obtain the recom-
mended CO2/CO rate.
- The pressure of the burner oil pump shall be
checked or adjusted via the hole ( 37) after remo-
ving the plug.
Fig. 60
- 38 -
COMMISSIONING
FCX 22 C
FCX 30 C
ST 108 FUV
ST 120 RV
Presetting
Max
at the
Preset
power
maximum
power
21,7
23,8
31,5
12
14
14
0,50 80°H
0,65 60°S
2,5
6,5
9,5
16
37
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcx 30 c

Table of Contents