Evacuation By Chimney Flue (B23/B23P/C33) - geminox FCX 22 C Technical Instructions

Hide thumbs Also See for FCX 22 C:
Table of Contents

Advertisement

Evacuation by chimney flue
3.2 -
C
)
33
An existing chimney flue can be used
!
provided that it is cleaned before the lin-
ing is fitted.
3.2.1 - Accessories
- order separately -
3.2.1.1 - Air trap kit
B
The air trap kit enables transformation of the boiler
to a version with a chimney.
See kit assembly guide
Fig. 7
Reference
3.2.1.2 - Bleed T-bracket and off-centre adapta-
tor ∅ 80/110.
Using the bleed T-bracket is mandatory in the B
configuration and is recommended in the B
configuration, especially with a long conduit (avoids
the return of a large volume of condensates via the
boiler).
Fig. 8
Reference
Length (mm)
Bleed T-bracket
380
V65.38981
off-centre reduction
155
(B
/B
23
23p
/B
23
23p
V65.38982
/C
23p
FCX-70-0
∅ (mm)
110
80/110
3.2.1.3 - adaptor ∅ 110./125
/
Fig. 9
Reference
V65.38983
3.2.1.4 - PPtl tubes
certification DE Z.7.-2-1051
Fig. 10
Reference
V72.28810
N40.26544
N40.33218
3.2.1.5 - Polypropylene elbow
certification DE Z.7.-2-1051
Fig. 11
23
33
Reference
V72.28808
A20.26543
N40.37320
3.2.1.6 - PVC air inlet pipe
Fig. 12
Reference
V72.28812
3.2.1.7 - Fastening collar (optional)
Fig. 13
Reference
B00.16088
- 14 -
INSTALLATION
FCX-80-0
∅ (mm)
Length (mm)
180
110/125
Length (mm)
1000
1000
2000
FCX-07-0
Type of elbow
90°
90°
45
Length (mm)
1000
Quantity
1
∅ (mm)
80
110
110
FCX-78-0
∅ (mm)
80
110
110
∅ (mm)
125
AM5-26-0
∅ (mm)
110

Hide quick links: