Do not operate heaters with incorrectly
fitted or damaged exhaust ducts.
8. Never allow the warm air outlet on the
heater to be obstructed in any way. For
instance never hang washing on or in
front of the heater to dry. Misusing your
heater in this way could cause serious
damage from overheating. Do not place
flammable objects near the heater.
Please follow these guidelines in the
interest of your own safety.
9. If the burner makes an unusual noise or if
the flame lifts off while burning, it is likely
that the regulator is faulty and it is
essential to have it checked.
10.Cleaning (with switched off appliance): It
is recommended that at least once a
year, before the heating season starts,
you remove any dust that has collected
on the heat exchanger base plate.
Technical Data:
Type of gas:
Liquid gas
(propane/butane)
Operating pressure:
30mbar (28mbar
butane, 37mbar
propane)
Rated thermal output: 3400W
Gas consumption:
30-280 g/h
Product Indent.
No: CE-0085AP0325
Automatic Ignitor
Power consumption:
50 MA (ignition)
0.01 MA
(monitoring)
Operating voltage:
3V
CHANGING OF BATTERIES
Changing the Batteries on the Automatic
Ignitor
Only change the batteries with the heater
switched off.
Always insert new batteries at the beginning
of the heating season.
Remove front of heater retaining screw,
located through centre of black grill. Unclip
front of heater, slide up battery cover to
reveal battery. Change the batteries.
Observe plus/minus.
Equipment Details
Only use temperature resistant (+70°C), leak-
proof Mignon round cells (LR 6, AA, AM 3,
Art. no. 30010-23600). Other batteries could
lead to malfunctions!

TRUMA ULTRAHEAT

ADDITIONAL ELECTRIC HEATING
FOR TRUMATIC S 3002 (P), S
5002 AND S 55 T HEATERS
Function description
Truma-Ultraheat is an additional 230V
electric heater for the LPG heater models
Trumatic S 3002/S 5002.
Heater operation is basically possible with
gas only, electricity only or simultaneously
with electricity and gas.
When using simultaneously the electrical unit
will switch itself off before overheating
occurs as a result of the stronger gas burner.
When using electricityl only we recommend
to set the fan control on position 3 (manual
or auto), remembering to set the output level
to 2000W (ensure that the fuse protection for
the power supply of the camp site is
sufficient).
If more than 2kW are required (heating
up/cold temperatures) you must refer back
using gas operations as the 230V electrical
operation is a secondary heater only.