About Advanced Features & Operation
EMERGENCY HEAT - Only available if you have a Heat Pump
installed. To initiate the Emergency Heat feature, press the OVERRIDE
button. While holding the OVERRIDE button press
Cool setpoint display will read 'EH' (emergency heat).
Press for
Emergency Heat
OVERRIDE
Operation - During Emergency Heat operation the thermostat will turn on the
fan and the 2nd stage of heat when there is a demand for heat. Also
during Emergency Heat, the 1st stage of heating or cooling will be
unavailable.
Exit Emergency Heat - Follow the same steps as entering Emergency Heat
by pressing the OVERRIDE and UP buttons. During Emergency Heat,
only OFF and HEAT modes are available by pressing the MODE button.
ENERGY SAVING SMART FAN - This feature allows the fan to run
continuously during Occupied 1, 2 or 3 and automatically de-energizes
during Unoccupied, except when necessary to heat or cool. To use this
feature, place the thermostat in the Program On mode. Next, program
the fan for continuous operation (step #3, page 14) to display the FanOn
icon (see below).