Injection diagnostic tool SYNERJECT
Info :
1- Transient failure/permanent failure: a transient error becomes permanent after a variable number of engine
cycles according to the component (injector, fuel pump, etc.). For a permanent error to disappear, wait 40 motor
cycles without the issue reappearing.
2- Fan error: if there is no fan installed on the motorbike, there will always be a fan error alarm (P0485).
3.4-
Clearing error codes:
A - If errors occur, go to the «Clearing Error Codes» menu.
• Confirm deletion of error codes via the icon